This  instruction  manual  contains  important 
information  about  the  installation  and  use  of  the 
projector.  Please  read  and  follow  these 
instructions carefully.
The  security  of  this  device  is  guaranteed  only 
with  the  proper  use  of  the  following  instructions, 
therefore they must be kept carefully.
Never  install  the  device  in  locations  easily 
accessible by people who ignore the existence of 
this user's manual and safety instructions.
Disconnect the unit from any power supply before 
attempting  any  operation  in  contact  or  inside  the 
unit, and when not in use.
Prior  to  connect  the  unit  to  the  power  supply, 
check  the  output  voltage  fits  the  technical 
requirements on the label.
Never  let  the  power  cord  come  into  contact  with 
other cables.
Never touch the electrical contacts, either directly 
with your fingers, or indirectly by means of sharp 
or metal objects.
Make sure that cables cannot cause trip hazard.
Do not attempt to dismantle and modify the unit.
Due  to  the  high  technological  level  of  this  unit, 
any service maintenance should be performed by 
specialised operators. Please contact your Arena 
Luci dealer for any operation.
Always ensure that the structure to which you are 
attaching the unit is secure and is able to support 
the weight of each unit.
Please  note  that  as  part  of  Arena  Luci's  ongoing  commitment  to  continuous  product  development, 
specifications  are  subject  to  change  in  the  course  of  product  improvement  without  notice. Arena  Luci  is  not 
responsible for damages resulting from improper or different use than expected.
LED INGROUND
Walk­over 230V ac LED inground

WARNINGS

Avoid installing the unit close to heat sources.
Never lean the power cord on hot unit surfaces.
Allowed  to  be  mounted  directly  on  inflammable 
surfaces.
Do  not  install  the  luminaire  on  deformed  or 
damaged surfaces.
The lighting apparatus must be used only with its 
protective shield.
Contact  your  Arena  Luci  dealer  if  the  protective 
shield is visibly damaged to the point at which its 
effectiveness  is  diminished,  for  example  by 
becoming cracked or deeply scratched.
LED module is not replaceable.
Do  not  use  any  solvent  based  cleaning  agents. 
Use only a soft, dry anti­static cloth.
The installation of LED modules (including power 
supplies)  should  be  done  according  to  current 
technical  rules  and  regulations.  The  installation 
should be performed only by a qualified operator.
This luminaire is an outdoor IP67 device, but not 
IP68  (underwater).  Therefore  the  proper  and 
extended functioning will be related to the proper 
installation.
To  avoid  infiltrations  inside  the  inground  box  do 
not  open  or  install  this  luminaire  during  rainy 
days or in high humidity conditions.
Avoid  contact  with  either  corrosive  agents  or 
humidity  and  moisture  on  delicate  elements: 
damages  from  corrosion  are  not  refunded  as 
component defects.
User's manual
FL0040
FL0042

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LED INGROUND and is the answer not in the manual?

Questions and answers

Summary of Contents for Arenaluci LED INGROUND

  • Page 1 LED INGROUND User's manual Walk­over 230V ac LED inground FL0040 FL0042 WARNINGS This  instruction  manual  contains  important  Avoid installing the unit close to heat sources. information  about  the  installation  and  use  of  the  Never lean the power cord on hot unit surfaces. Allowed  to  be  mounted  directly  on  inflammable  projector.  Please  read  and  follow  these  instructions carefully. surfaces. The  security  of  this  device  is  guaranteed  only  Do ...
  • Page 2 LED INGROUND TRANSPORT AND SHIPPING B ­ the bottom layer of the installation should be ma­ Open the shipping carton and verify that all equip­ de with a material with proper draining capability. ment necessary to operate the system has arrived  C  ­  the  shunt  from  the  230  V AC  line  should  be  intact.  Refer  to  the  following  packing  list  for  performed using an IP68 rated cast resin joint. information  on  what  items  are  included  with  your  D ­ the connection between the 230 V AC line and  model.  If  any  equipment  is  missing  or  damaged,  the ...
  • Page 3 USER'S MANUAL all  the  standards  of  good  practice  and  safety  regulations. The  absorption  of  a  single  device  is  10W  at  full  capacity. The FL0040 / FL0042 models cannot be powered  by dimming control devices, as the internal power  supply may be damaged. With  long  chains  of  LED  illuminators  it  is  recommended  to  use  cable  sections  of  at  least  2.5mm POWER SUPPLY Disconnect the mains voltage from the system.
  • Page 4 The  device  meets  the  essential  requirements  of  materials will help to conserve natural resources. For  the  Directives  LVD  2014/35/UE,  EMC  more  detailed  information  about  recycling  of  this  2014/30/UE,  RAEE  2012/19/UE,  RoHS  product,  please  contact  your  city  office,  your  2011/65/UE,  Ecodesign  2009/125/CE  ­  reg.  (UE)  household waste disposal service or your supplier. Arena Luci srl via Svizzera 12/14 ­ 46042 Castel Goffredo (MN), Italy Tel. +39 0376 782411 ­ Fax +39 0376 780973 www.arenaluci.com ­ info@arenaluci.it...

This manual is also suitable for:

Fl0040Fl0042

Table of Contents