Download Print this page

Operation - Pilot Air TM325I Instructions And Parts List

Advertisement

Ensure ON/OFF switch is located on the pressure switch is in an
OFF position (down), before inserting power plug into appropriate
power point and applying power.
Unit can then be switched on using the ON/OFF switch. The
pressure switch will automatically start and stop the compressor
when the air receiver drops below or reaches factory set cut-in
and cut-out pressures respectively.
ALWAYS SWITCH UNIT ON AND OFF VIA
PRESSURE SWITCH TO ENSURE THE UNIT
DOES NOT START AGAINST HIGH PRESSURE
TO PREVENT DAMAGE TO UNIT OR PERSONS DO NOT
ATTEMPT TO MODIFY, BYPASS OR REMOVE PRESSURE
SWITCH OR SAFETY VALVE IN ANY WAY.
"TM" OR "K" SERIES ARE DESIGNED TO OPERATE TO
A MAXIMUM PRESSURE OF 10 BAR.
The air receiver is equipped with a safety valve to release
pressure in the event of a pressure switch cut-out failure. To
prevent damage to the unit, do not attempt to modify, bypass or
remove the pressure switch or safety valve in anyway.
The motor features a manual overload protection (where fitted).
In poor power conditions or motor over temperature conditions,
this overload protector will cut power to the motor. To reset,
wait for the motor to cool then press reset button. If problems
persist, check for power ratings, faulty power or poor
connections.

OPERATION

ELECTRIC UNITS
p : 1300 667 579
www.pilotair.com.au

Advertisement

loading