Unit Identification; Safety Considerations - Carrier Infinity 24VNA6 Series Service Manual

Variable speed air conditioner and heat pump
Hide thumbs Also See for Infinity 24VNA6 Series:
Table of Contents

Advertisement

24VNA6 / 25VNA4: Service Manual

UNIT IDENTIFICATION

The unit is identified using a 16 digit model number structure. It is recommended providing the complete 16 digit model number when ordering
replacement parts to insure receiving the correct parts.
1
2
3
4
2
4
V
N
Product
Product Series
Tier
Family
24=AC
V=Variable
Infinity
25=HP
Speed
Series
01
Week of
Manufacutre

SAFETY CONSIDERATIONS

Installation, service, and repair of these units should be attempted only
by trained service technicians familiar with standard service instruction
and training material.
All equipment should be installed in accordance with accepted practices
and unit Installation Instructions, and in compliance with all national and
local codes. Power should be turned off when servicing or repairing
electrical components. Extreme caution should be observed when
troubleshooting electrical components with power on. Observe all
warning notices posted on equipment and in instructions or manuals.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing, modifying, or servicing system, main electrical
disconnect switch must be in the OFF position. There may be more than
1 disconnect switch. Lock out and tag switch with a suitable warning
label.
WARNING
!
ELECTRICAL HAZARD - HIGH VOLTAGE!
Failure to follow this warning could result in personal injury or death.
Electrical components may hold charge. DO NOT remove control box
cover for 2 minutes after power has been removed from unit.
PRIOR TO TOUCHING ELECTRICAL COMPONENTS:
Verify less than zero (0) vdc voltage at VFD connections shown on
cover.
CAUTION
!
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear
appropriate protective clothing and gloves when handling parts.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Model Number Nomenclature
5
6
7
A
6
3
Major
SEER
Cooling
Series
Capacity 1,000
A =
6 = Up to 26 SEER
Btuh (nominal)
Puron
4 = Up to 24 SEER
SERIAL NUMBER NOMENCLATURE
18
Year of Manufacture
8
9
10
11
6
A
0
0
Variations
Open
Open
A =
0=Not
0=Not
Standard
Defined
Defined
E
Manufacturing Site
E = Collierville, TN
X = Nonterey Mexico
!
UNIT OPERATION AND SAFETY HAZARD
Failure to follow this warning could result in personal injury or
equipment damage.
Puron® (R-410A) systems operate at higher pressures than standard
R-22 systems. Do not use R-22 service equipment or components on
Puron equipment. Ensure service equipment is rated for Puron®.
Refrigeration systems contain refrigerant under pressure. Extreme
caution should be observed when handling refrigerants. Wear safety
glasses and gloves to prevent personal injury. During normal system
operations, some components are hot and can cause burns. Rotating fan
blades can cause personal injury. Appropriate safety considerations are
posted throughout this manual where potentially dangerous techniques
are addressed.
If you do not understand any of the warnings, contact your product
distributor for better interpretation of the warnings.
General information
The Greenspeed Intelligence heat pump and air conditioner features the
latest variable speed technology. The heart of the system is the Samsung
high side rotary or scroll variable speed compressor powered through the
use of the Samsung variable frequency drive (VFD) control. By
combining the Primary Control Module (PCM), an ECM outdoor fan,
Samsung VFD, Samsung variable speed compressor and the Infinity
Series outdoor cabinet, the HP unit achieves a Seasonal Energy
Efficiency Ratio (SEER) of up to 24 and up to 13 Heating Seasonal
Performance Factor (HSPF) and the AC achieves up to 26 SEER.
To ensure all of the above technology provides the ultimate in comfort, it
is combined with either a fan coil or Variable Speed Gas furnace
controlled with a two wire communication Infinity wall control.
2
12
13
14
3
0
0
Minor
Compressor
Voltage
Open
Series
Identification
0=Not
4=VS Scroll
3=208/230-1
Defined
5=VS Rotary
00001
Serial Number
WARNING
15
16
0
0
Open
0=Not
Defined

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Infinity 25vna4 series