Advertisement

Quick Links

CADI SmartSense
SmartNODE
SMN-823W User Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Cadi SmartNODE SMN-823W

  • Page 1 CADI SmartSense SmartNODE SMN-823W User Manual...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents ........................... 2 1. Introduction ..........................5 2. Specifications ..........................5 3. Button Usage ..........................5 4. First install on soap dispenser..................... 7 5. To change new battery........................ 8 6. To change new soap liquid....................... 11 7.
  • Page 3 Regulatory Information For customers in U.S.A and Canada Federal Communications Commission (FCC) Statement 15.21 Warning: You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. 15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.
  • Page 4 This version is subject to change or upgrade without notice • Version: A03 • Issue date: 20 Aug 2019 Declaration Cadi Scientific Pte Ltd reserves the right to change the product described in this Operator’s Manual. All information contained in this Operator’s Manual is subject to change without notice.
  • Page 5 Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the ME Equipment or ME System, including cables specified by the manufacturer.
  • Page 6: Introduction

    1. Introduction The SMN-823W is a battery operated motion sensing tag. The SMN-823W transmits LF signal upon detection of motion to trigger close proximity communication to other tags. SMN-823W is designed to be installed onto automatic soap dispensers to allow Hand Hygiene Compliance in hospitals and clinics. When the SMN-823W detects motion, it will transmit a unique ID using low frequency.
  • Page 7 User button SLEEP->WAKE Initialize Activation Count Used to initialize the soap usage level to 0 when doing a soap refill Explanation: Activation Count (soap level) will be maintained until the user physically initiates a WAKE->SLEEP->WAKE sequence using the User button. Or else, the Activation Count remains. START WAKE mode SLEEP mode...
  • Page 8: First Install On Soap Dispenser

    START Reset button pressed? Initialise Tx count, Battery Level 4. First install on soap dispenser 1. Ensure the tag is in SLEEP mode (no LED blinking). If not, long press (5sec) the User button. 3 beeps are heard, Red LED blinks once. 2.
  • Page 9 3. Install the tag onto the bracket. 4. Long press (5sec) the User button to WAKE the tag. 3 beeps are heard, Green LED blinks once, then starts blinking periodically. Result: 1. Usage level of the soap (Activation Count) will be reset to 0.
  • Page 10: To Change New Battery

    5. To change new battery 1. Remove the tag from the dispenser (2 screws). 2. Unscrew the tag (6 screws) and remove the back cover. 3. Disconnect the existing battery. 4. Connect the new battery. Press the Reset button once (5 beeps are heard).
  • Page 11 5. The tag will automatically default to WAKE mode. Confirm the tag is in WAKE mode by observing the blinking Green LED. 6. Replace the back cover and screw. 7. Install the tag back into the bracket.
  • Page 12: To Change New Soap Liquid

    Result: 1. Usage level of the soap (Activation Count) will be maintained. 2. Transmit Count (wifi), and Battery Level will be reset. 6. To change new soap liquid 1. Put the tag to SLEEP mode (long press the User button until 3 beeps are heard, red LED blinks once).
  • Page 13: To Remove Tag For Cleaning (No Change Of Liquid Soap)

    Result: 1. Usage level of the soap (Activation Count) will be reset to 0. 7. To remove tag for cleaning (no change of liquid soap) 1. Remove the tag from the dispenser for cleaning. 2. Install the tag back into the bracket.
  • Page 14: Using The Tag

    Result: 1. All parameters will remain as no buttons are pressed. 8. Using the tag The tag requires both vibration and proximity sensing to successfully activate. When mounted on the soap dispenser, when the staff puts his hand under the dispenser, the motor from the dispenser will activate the motion sensor, at the same time, the presence of the staff’s hand will activate the proximity sensor.
  • Page 15: Low Battery Behaviour

    Vibration Proximity Hand wash Unsuccessful Unsuccessful Unsuccessful Successful 9. Low battery behavior...
  • Page 16 The tag continuously monitors the battery level. The battery capacity percentage is reported via wifi, and the low battery status can be viewed on the LED window. The LED will blink periodically in red instead of green. The tag will also report low battery status if it was internally restarted due to low battery.