Advertisement

Model 82400SS User's Manual
Model 82400SS
Master Shocker Supply
User's Manual
3700 Sagamore Parkway North
P.O. Box 5729 • Lafayette, IN 47903 USA
Tel: 765.423.1505 • 800.428.7545
Fax: 765.423.4111
E-mail: info@lafayetteinstrument.com
www.lafayetteinstrument.com
1
Fax: 765-423-4111 . www.lafayetteinstrument.com . E-mail: info@lafayetteinstrument.com
Copyright © 2003 by Lafayette Instrument Company, Inc. All Rights Reserved. 12.2.05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 82400SS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lafayette Instrument 82400SS

  • Page 1 3700 Sagamore Parkway North P.O. Box 5729 • Lafayette, IN 47903 USA Tel: 765.423.1505 • 800.428.7545 Fax: 765.423.4111 E-mail: info@lafayetteinstrument.com www.lafayetteinstrument.com Fax: 765-423-4111 . www.lafayetteinstrument.com . E-mail: info@lafayetteinstrument.com Copyright © 2003 by Lafayette Instrument Company, Inc. All Rights Reserved. 12.2.05...
  • Page 2: Specifications

    DESCRIPTION The 82400ss was designed to provide a wide range of shock currents continuously variable from 0 to 5 mA. This shocker was designed to accommodate subject resistances from 0 to 100,000 ohms and are capable of delivering a full 5 milliamperes to a 100,000 ohm subject.
  • Page 3 Model 82400SS User’s Manual grid harness input, or other shock administering device. 4. Connect a suitable initiation device such as remote pushbutton, COM-N.O. timer contacts, solid state driver (+ to red binding post, and to black binding post) or other switching device to these initiate binding posts.
  • Page 4 Lafayette Instrument Master Shocker Supply The above current values are RMS or Root Mean Square current. This is common practice; however, occasionally a study will give results in terms of average current, peak current, or peak to peak current. The following table may be used to convert any of these values to any other value by using the given multipliers.
  • Page 5 In this case the % Regulation is equal to [(1.0 – 1.2)/1.0] x 100 or 20%. This design would not be considered very satisfactory. Below is the equivalent circuit for the Lafayette Shockers number 82400SS. When the subject’s resistance equals 100,000 ohms the current flow is 1 mA. When the subject’s resistance equals 0 ohms the current flow is 1.04 mA.
  • Page 6: Ordering Information

    DOMESTIC TERMS or abuse, normal wear or accident. In no event shall Lafayette Instrument be There is a $50 minimum order. Open accounts can be extended to most liable for incidental or consequential damages. There are no implied warranties recognized educational institutions, hospitals and government agencies.