Micron SCORPION Z4120 User Instructions

Advertisement

Quick Links

As installed by Eagle Alarms
Using the Scorpion Z 4120C alarm controllers

The Keypad

The Scorpion Z4120C and Z8020C communicate system status through the keypad beeper. During an arming cycle the
beeper will sound for the entire exit time. This is a 'leave now' warning. Scorpion will arm at the expiry of this period.
On entry, the beeper sounds for the programmed entry period. If a valid user code is entered to disarm the system, the
beeper emits two short tones. An incorrect entry is signalled by one long tone.
The 'Status' Lamp
The yellow status lamp is used to indicate several conditions.
Yellow lamp on:
Yellow lamp off:
Yellow lamp flashing:
The 'Mains' Lamp
The 'Mains' lamp is on when mains power is applied. In the event of a mains failure the 'Mains' light flashes until
mains power is restored, and an arm/disarm cycle is completed. The 'Mains' lamp also flashes to indicate a low battery
condition. When the battery is restored to full charge and an arm/disarm cycle is completed, the 'Mains' lamp stops
flashing.
The 'Armed' Lamp
The 'Armed' lamp illuminates when the system is armed. The 'Armed' lamp also flashes to indicate when an alarm
condition has occurred.

User Codes

Scorpion Z4120C and Scorpion Z8020C are each capable of storing up to twenty-four user codes. Each user code may
be two to four digits in length and each may be programmed with one or all of six different functions. Each user code
may be programmed:
As a user code that can arm and/or disarm the system from a touch tone phone
As a user code that can select a partitioned area to arm (Z8020C only)
As a master user code that can program other user codes
As an arming code only (can not disarm the system)
As a user code that does not report to a central station
As a user code that can exclude zones at arming.
If no option is selected for a user code, that code will perform a basic arm and disarm function only.
User code 1 is factory set as a master user code 1234 and should be changed to your own selection. This user code can
also be used to program the remaining user codes. Your installer will need to assign the functions of each additional
user code when your system is installed. For example you may require user code 18 to be used by a domestic helper to
SCORPION
Z4120 Alarm Controller
09 5357117
www.eaglealarms.co.nz
User Instructions
the system is armed or arming
the system is disarmed
an alarm has occurred, a system fault exists or
the panic function has been activated

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCORPION Z4120 and is the answer not in the manual?

Questions and answers

Summary of Contents for Micron SCORPION Z4120

  • Page 1 SCORPION Z4120 Alarm Controller As installed by Eagle Alarms 09 5357117 www.eaglealarms.co.nz User Instructions Using the Scorpion Z 4120C alarm controllers The Keypad The Scorpion Z4120C and Z8020C communicate system status through the keypad beeper. During an arming cycle the beeper will sound for the entire exit time.
  • Page 2 arm but not disarm the system. This restriction on code 18 will need to be pre-set by the installer. The code may be entered at a later time using the master code. Use the user code attributes table in the rear of this user manual to record the functions for each code.
  • Page 3 Zone 6 lamp flashes Siren output or auxiliary power supply overloaded or open circuit Hold Down Commands To use a ‘hold down’ command the function key (keypad digit) must be pressed and held down until a 2 key-beep is heard. Note that hold down commands will ONLY function when the alarm control is fully disarmed. The following hold down commands are available: Setting the Real Time Clock Time It is advisable but not mandatory to set the system Real Time Clock.

This manual is also suitable for:

Scorpion 4120c

Table of Contents