Product Features Two „user selectable‟ night arming options. a. Perimeter (instant) arming with no delay. b. Perimeter arming with entry and exit delay. 02. Auto arming at programmed time (end user can set time for arming). Auto arm in Away mode. Auto arm in Home mode.
Keypad Commands & Functions KEYPAD ENTRY COMMAND 1# or 2# Quick arm Smoke reset 71# or 72# Chime mode On/Off Alarm history recall 81# or 82# Instant perimeter arm, instant alarm Panel status recall 91# or 92# Night (perimeter) arm with delays Force panel to answer call 99# + nnnnnnn Panel dials nnnnnnn...
(two beeps) then press the # key within 6 seconds. The panel will jump directly to „Program‟ mode. If this function has been disabled at Loc. 410 the panel can not be accessed and must be returned to a Micron master distributor.
Other Panel Functions A brief explanation of functionality is given for each memory location in the section headed Programming. This section provides more detail for some of the 4120, 6020 and 8020 features and functions. How the 24 Hour Zones Work Important, read this carefully.
Using the ‘Hold Down’ Commands To use a „hold down‟ command the function key (digit) must be pressed and held down until a second key-beep is heard. Note that all hold down commands operate ONLY when the panel is fully disarmed. The installer or the end user may use the following functions.
Abort Current Communication The following function aborts communication currently in progress and clears all outstanding events from the reporting buffer. Events deleted from the buffer are still retained in the event history file. Press and hold down the 0 key till a second beep is heard then enter a Master user code then #. [Hold-0] 1234 # Communication in progress stops immediately.
Page 10
LOCATION CONTENTS & FIELD SIZE REMARKS User 24 code (4 digits) Installer code (4 digits) Default 0000 Area A account (4 digits) Area B account (4 digits) Auto-arming time (4 digits) See also Locs 347,412 Default 9999 Upload/download password (4 digits) Default 5555 Test signal time (4 digits) Default 9999...
Page 11
LOCATION CONTENTS & FIELD SIZE REMARKS Medical panic code (2 digits) Arming failure (2 digits) Reserved User code changed (2 digits) User initiated test code (2 digits) Line fault code (2 digits) Line restore code (2 digits) Comms fail code (2 digits) AC Power failure code (2 digits) AC Power restore code (2 digits) Battery test fail code (2 digits)
Page 12
LOCATION CONTENTS & FIELD SIZE REMARKS Area B entry delay (1 digit) Z8020C only As above Area A alternate entry delay (1 digit) As above Area B alternate entry delay (1 digit) Z8020C only As above Spare (2 digits) Siren output timer (1 digit) Default 5 (minutes) Erased: no timeout 1-15: 1 to 15 minutes...
Page 13
LOCATION CONTENTS & FIELD SIZE REMARKS Entry delay zones select (toggle) Default 1 Alternate entry zones select (toggle) Follower entry zones select (toggle) Swinger shutdown zones select (toggle) Default All zones Cross zones select (toggle) Pre-alert zones select (toggle) Default 1 Chime zones select (toggle) Select outputs to mimic key beeps Led 1: Siren output...
Location 160 Master Programming Code. This is a 4 digit code used to enter programming mode. Micron suggests leaving this code at 0 0 0 0 until all other programming is complete and tested. Do not forget to change the code when the panel is installed and commissioned.
Page 16
Location 168 Area B Account Number. If the panel has been partitioned, enter the Area B account number here. [Z8020C only] Location 172 Auto Arming Time. Enter the time of day for the panel to auto arm. The time must be entered in 24Hour format, example: 2030 is 8.30pm or 0750 is 7.50am.
Locations 316 – 324 Single Digit Reports [ Non Contact ID ] Enter a single digit for each of the reports required. The panel will automatically append a second digit to the report that will identify the zone or user ID. Note that in Loc. 319 and 320, if the panel is programmed for „Slow Speed‟ or DTMF 4 + 2 reporting format, the communicator can not report user ID‟s above User 15.
Zone Options - Programming Location 364 Cross Zoning [Double Knock] There are 4 options. Enter 1 digit to select. Erased: No cross zones 2 activations on the same zone 2 activations on 2 different zones 2 activations on the same zone or 2 different zones Location 365 Cross Zoning Timer Enter a value in the range 1 to 15 minutes.
Location 400 Pre-alert Zones Select Select zones that will activate the keypad beeper during entry. Zones selected must also be selected at Locs. 374 or 376 and 390, 392. Location 402 Chime Zones Select Select zones to activate the keypad beeper when the panel is unset and chime mode is turned on. System Settings - Programming Location 404 Output Mimics Keypad Beeper Outputs selected here will mimic the keypad beeper eg.
Location 418 Zones to Activate the Aux. Output 2 The same rules apply here as at Loc. 414 except that the Aux. 2 output will be enabled. Location 420 System Events to Activate the Siren Output Led 1 On: NiteWatch panic. Led 2 On: Two key panic.
Location 480 Key Switch Arming Reports Led 5 On: Does not report. Off: Reports Arming by Key Switch as User 27. Location 482 Auto Arm Reports Led 5 On: Does not report. Off: Reports Auto Arming as User 28. Using the Follow Me Function (Home Dial) If “Follow Me”...
This table shows the approximate current draw by micron alarm accessories configured to Scorpion alarm controllers during alarm activation. It is important to calculate total current draw when configuring micron systems to ensure power supplies are not overloaded during activation.
Technical Specifications AC Input …………………16VAC from transformer (do NOT exceed) Accessory Power ……….13.8VDC. 500mA total drain. Aux. Output 1…………… Max. 250mA Sink output. Aux. Output 2…………… Max. 250mA Sink output. Siren Output……………...Max. 1.5 Amps DC to non inductive load or: 2 x Siren speakers with built in driver @ 350mA per siren.
Page 24
Subject to clause 2 below, Micron guarantees this product against defects in materials and workmanship for a period of 24 months from the date of delivery to the purchaser as follows: (a) Micron will repair or replace free of charge any goods or part thereof found to be defective by reason of faulty material or workmanship.