TERSO TS097 User Manual

TERSO TS097 User Manual

Undercounter rfid refrigerator

Advertisement

Quick Links

Undercounter
RFID
Refrigerator
TS097
Undercounter RFID Refrigerator User Guide, Rev 5 – 06/18/2021
PN 720509
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS097 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TERSO TS097

  • Page 1 Undercounter RFID Refrigerator TS097 Undercounter RFID Refrigerator User Guide, Rev 5 – 06/18/2021 PN 720509...
  • Page 2 THIS PAGE INTENTIONALLY BLANK Undercounter RFID Refrigerator User Guide, Rev 5 – 06/18/2021 PN 720509...
  • Page 3 Terso Solutions Undercounter RFID Refrigerator Terso Solutions, Inc. 5540 Research Park Drive Madison, WI 53711 U.S.A. Terso Solutions GmbH Gutenberging 10 69190 Walldorf Germany US: +1 888.376.0257 EU: +49 621.8501.233 Undercounter RFID Refrigerator User Guide, Rev 5 – 06/18/2021 PN 720509...
  • Page 4 THIS PAGE INTENTIONALLY BLANK Undercounter RFID Refrigerator User Guide, Rev 5 – 06/18/2021 PN 720509...
  • Page 5 Terso Undercounter RFID Refrigerator User Manual Undercounter RFID Refrigerator User Guide, Rev 5 – 06/18/2021 PN 720509...
  • Page 6: Table Of Contents

    TABLE OF CONTENTS ABOUT THIS MANUAL …………………………………………………………………………………………… 7 Introduction ……………………………………………………………………………………………………… 7 Notational Conventions ………………………………………………………………………………...……… 7 PRECAUTIONS FOR SAFE OPERATIONS ………………………………………………………………...… 7 GETTING STARTED ………………………………………………………………………………………….… 10 Components …………………………………………………………………………………………………… 10 Unpacking the Device ………………………………………………………………………………………… 10 Installation ……………………………………………………………………………………………………… 11 Operating Instructions ………………………………………………………………………………………… 12 Device Alarms ……………………………………………………………………………………………….…...
  • Page 7: About This Manual

    Read this guide carefully before operating the TS097 Undercounter RFID Refrigerator and follow instructions for safe operation. Terso Solutions does not guarantee safe operation if the device is not used as intended as outlined in this guide. The contents of this guide are subject to change without notice due to improvement in performance or functions.
  • Page 8 This mark indicates the location of the protective earth conductor. Do not disconnect. Disconnection of the protective earth conductor may impair the protection provided by the device. Risk of shock is present inside the device. The cover should be removed by qualified engineers or •...
  • Page 9 Disconnect the power supply plug if there is something wrong with the device. Continued abnormal • operation may cause electric shock or fire. If the device is to be stored unused in an unsupervised area for an extended period, ensure that children •...
  • Page 10: Getting Started

    Inspection Before unpackaging the device, inspect for any damage that may have occurred during transit. If any damage is present, please contact Terso Solutions Technical Support at +1 888.376.0257. Unpacking Remove the straps and remove all packaging. Gently position the device in place on the ground.
  • Page 11: Installation

    Proper Handling Do not use the handle to pull the device. Always move the device with the door facing you. Carefully roll the device into position leaving at least a 1 inch (in.) gap between the device and the back wall. The device is designed with a “front breathing”...
  • Page 12: Operating Instructions

    The controller has been factory set and tested to allow your device to operate at its desired temperature cycle. Please consult the manufacturer’s documentation for additional instructions on using the temperature controller. Adjusting the settings on the controller will override the factory settings. It is recommended to consult with Terso’s technical support department prior to adjusting controller.
  • Page 13: Device Alarms

    Device Alarms All device alarms are automatically sent to Terso Solutions. Terso Solutions’ staff may contact on site staff to assist in correcting a potential problem. Alarm Types Door Ajar When the device’s door is left open for longer than one minute, an audible alarm will sound, and the LCD display will show “Please close door”...
  • Page 14: Troubleshooting

    If the device appears to not be operating correctly, check to ensure that it is plugged into a wall outlet and powered on. If further support is needed, contact Terso Technical Support at +1 888.376.0257. Support can also be contacted by visiting http://support.tersosolutions.com.
  • Page 15: Appendix A: Device Specifications

    APPENDIX A: DEVICE SPECIFICATIONS FEATURE SPECIFICATION ELECTRICAL REQUIREMENTS Electrical power & frequency 115 VAC, 60 Hz, 2 A Power consumption 1.5 kW/day (average) RFID battery backup 12 VDC SLA, qty 2 SECURITY Security mechanism Electronic door latch Access control LF/HF pass reader COMMUNICATIONS Connection...
  • Page 16: Appendix B: Model Specifications

    APPENDIX B: MODEL SPECIFICATIONS MODEL COUNTRY PLUG STYLE TS097 NEMA 5-15 Undercounter RFID Refrigerator User Guide, Rev 5 – 06/18/2021 PN 720509...
  • Page 17: Appendix C: Saftey Checklist

    APPENDIX C: SAFTEY CHECKLIST Please fill out this form before servicing and ensure that the device is properly marked with any applicable markings to denote any hazards inside. Provide this form to the service engineer to keep for safety purposes. SAFETY CHECKLIST Refrigerator Contents: Risk of infection …………………………………………………...
  • Page 18: Appendix D: Warranty

    Device that has been modified to alter functionality or capability without the written permission of Terso; (h) to defects caused by normal wear and tear or otherwise due to the normal aging of the Terso Device, (i) if any serial number has been removed or defaced from the Terso Device;...