1 GENERAL INFORMATION

This manual contains information necessary for the proper operation of the pump in order to prevent unsuitable use
and for the safety of the operators.
Do not attempt any other type of operation without having first contacted our Service Department.
The information provided herewith does not intend to replace, integrate or change any rules, regulations, law by
decree, directive or law of specific character in force in the Country where the installation takes place.
The suggestions given to the staff engaged in the installation and servicing assumes that the personnel is expert
and prepared in facing any problem of servicing, both mechanical and electrical.
For any questions or information not included in this manual, please contact our Service Department, always
providing: model (type), serial number, year of manufacture, stated on the name plate.
In the manual two symbols are used:
ATTENTION:
Instructions that, if not followed, could result in serious personal injuries.
WARNING:
For instructions that, if not followed, could cause damages to the machine..
Hot surfaces
Electrical danger

2 PRODUCT SPECIFICATIONS

2.1 Pump description

PHV K pump series are rotary vane oil lubricated two stage vacuum pumps.
The flanged electric motor is coupled by means of an elastic coupling.
The cooling is made by means of forced air by a centrifugal fan.
At the inlet there is a mesh filter in order to protect the pump from solid parts.
An integrated non-return valve prevents the oil from going back and the return of air in the camber to be pumped
down during the stop phase.