Specifications - Bostitch CAP60PB-OF Operation And Maintenance Manual

Table of Contents

Advertisement

ELECTRICAL GROUNDING INSTRUCTIONS: (continued)
DUTY CYCLE:
To ensure long life of your BOSTITCH air compressor, do not operate on more than a 50% duty
cycle. If this air compressor pumps air more than 50% of one hour, then the compressor's
capability is less than the air delivery required by the application. Always match the air
volume requirements of the attachment or accessory with the air volume delivery of the
compressor.
Notice!: BOSTITCH does not recommend the use of extension cords with compressors. The
use of an extension cord can result in the loss of voltage supplied to the compressor which
could prevent the compressor from starting. For optimum performance, plug the compressor
directly into an outlet and increase the length of airline as needed.
If an extension cord must be used, use these guidelines:
CAP60PB-OF
Motor:
Fuse Requirements:
Operating Pressure:
Safety Valve Setting:
Air Delivery:
Maximum Amps at Working Pressure:
Tank Size:
Air Outlet:
Pressure Switch Settings:
Weight:
PSI = Pounds Per Square Inch:
Distance Needed
Less than 25 ft.
25 - 50 ft.
Greater than 50 ft.
Recommended Gauge
12 Gauge
10 Gauge
Not Recommended
6

SPECIFICATIONS

2HP (Peak) / 1.5HP (Running)
115V – 60HZ
15 Amps minimum
0 – 135 PSI
150 PSI
3.4 CFM @ 40 PSI
2.1 CFM @ 90 PSI
11.3
6 Gallons
1/4" NPT
On @ 105 PSI
Off @ 135 PSI
37lbs.
CFM = Cubic Feet Per Minute

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents