THE SEMI-AUTOMATIC TARE OPERATION IS LOST UPON INSTRUMENT POWER-
OFF.
To perform a net operation (SEMI-AUTOMATIC TARE), close the NET/GROSS input or press the
TARE f key for less than 3 seconds. The instrument displays the net weight (just set to zero) and the
NET LED lights up. To display the gross weight again, keep the NET/GROSS input closed or press
TARE for 3 seconds.
This operation can be repeated many times by the operator to allow the loading of several products.
Example:
Put the box on the scale, the display shows the box weight; press TARE, the display shows the net
weight to zero; introduce the product in the box, the display shows the product weight. This
operation can be repeated several times.
While the net weight is displayed, keep
the key is released the net weight will be displayed again.
The semi-automatic tare operation is not allowed if the gross weight is zero or negative or
unstable or above the maximum capacity.
Function not available if net functions are disabled (see parameter
INFO MENU).
It is possible to manually set a preset tare value to be subtracted from the display
value provided that the
interval instruments, the max permitted value is Max1 (max capacity of range 1).
By default the instrument shows the last programmed preset tare value: to apply it press ENTER.
After setting the tare value, going back to the remote display, the display shows the net weight
(subtracting the preset tare value) and the NET LED lights up to show that a tare has been entered.
To delete a preset tare and return to gross weight display, hold down TARE for about 3 seconds or
keep the NET/GROSS input (if any) closed for the same length of time (3 seconds). The preset tare
value is set to zero. The NET LED is turned off when the gross weight is displayed once again.

SEMI-AUTOMATIC TARE (NET/GROSS)

PRESET TARE (SUBTRACTIVE TARE DEVICE)

pressed to display gross weight. When
≤ max capacity condition is verified. In multi-
- 17 -