Simple Power On Sequence (DX Series)
< DX series >
Also 16V is necessary before Power LED on at first time.
( Plug in )
STB5V output
TV_SUB_ON signal
16V / 32(*)V output / PFC circuit start working
Power On
Power LED Green
PANEL_VCC_ON2 signal
PNL12V output
BL_ON_ON signal
16V / 32(*)V up to VLED
< Display start >
Standby
Power Off
Power LED Red
Power LED off
TV_SUB_OFF
TV_SUB_OFF
Stop 16V / 32(*)V
Stop 16V / 32(*)V
Power SW on / Remote on
North America :
(Power LED Green RED)
(Power LED Red OFF)
(Power Off no exist)
(*) The DC level is different by the LCD panel.
AC Plug in
STB5V (form P to A)
SUB_ON (from A to P)
16V (from P to A)
Power LED
Panel_Vcc_ON (from A to Panel(TCON))
PNL12V (from A to Panel(T-CON) )
BL_ON (from A to Panel(Backlight))
VLED (from P to Panel(Backlight) )
5V
Power on
(Standby)
Power on
16V
(Standby)
Standby / Power on
Power on
12V
VLED
Ex.24V