Simple Power On Sequence (D/DS Series)
< DS/D series >
( Plug in )
STB5V output
Power On
Power LED Green
TV_SUB_ON signal
PFC circuit ( IC7201/T7201 ) start working
16V / 32(*)V output
PANEL_VCC_ON2 signal
PNL12V output
BL_ON_ON signal
16V / 32(*)V up to VLED
< Display start >
Standby
Power Off
Power LED Red
Power LED off
Power SW on / Remote on
North America :
(Power LED Green RED)
(Power LED Red OFF)
(Power Off no exist)
(*) The DC level is different by the LCD panel.
AC Plug in
STB5V (form P to A)
Standby / Power on
Power LED
SUB_ON (from A to P)
16V (from P to A)
Panel_Vcc_ON (from A to Panel(TCON))
PNL12V (from A to Panel(T-CON) )
BL_ON (from A to Panel(Backlight))
VLED (from P to Panel(Backlight) )
5V
Power on
(Standby)
16V
12V
VLED
Ex.24V