Midea MEHS-09NIH2 Service Manual page 59

Table of Contents

Advertisement

3. IPM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
(+)Red
(-)Black
N
U
P
V
W
4: Indoor AC Fan Motor
Measure the resistance value of each winding by using the tester.
Position
RPG13B
Black -
530Ω±8%
Red
(20℃/68℉)
(Brand:
Welling)
White -
315Ω±8%
Black
(20℃/68℉)
(Brand:
Welling)
Normal resistance value
(Several MΩ)
RPG15A
RPG20B
75Ω±8%
381Ω±8%
(20℃/68℉)
(20℃/68℉)
(Brand:
(Brand:
Welling)
Welling)
150Ω±8%
267Ω±8%
(20℃/68℉)
(20℃/68℉)
(Brand:
(Brand:
Welling)
Welling)
Digital tester
(+)Red
(-)Black
U
V
N
W
(+)Red
Resistance Value
RPG28H
183.6Ω±8%
(20℃/68℉)
(Brand:
Welling)
206Ω±8%
(20℃/68℉)
(Brand:
Welling)
57
Normal resistance value
(Several MΩ)
RPG45B
112Ω±8%
118.5Ω±8%
(20℃/68℉)
(20℃/68℉)
(Brand:
(Brand: Broad
Welling)
Ocean)
82Ω±8%
78.5Ω±8%
(20℃/68℉)
(20℃/68℉)
(Brand:
(Brand: Broad
Welling)
Ocean)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents