Specifications

Operating Voltage: 12 ~ 24 VDC/AC
Current Draw: 280mA/12VDC; 180mA/24VDC
Locking Mode: Fail-Safe
Operating Temperature: -10°C~+49°C
Humidity: 0~85% non-condensing
Applicable to horizontal and vertical installation
For single/double action swing doors
Latch Throw: 13mm
Endurance Rating: 250,000 cycles (Factory tested)
Static strength: 1,500 lbs
Preload: 500 lbs of pressure strength
ML-450 Series Models
ML-450M: Mortise mount
ML-450MSMB: Surface mount
ML-450MVGL: Surface mount (for frameless glass doors & walls)
Strike Plate Dimensions
KP-ML-400-A
KP-ML-400-B

Wiring Diagram

ML-450 Electric Lock
Installation Instruction
KP-ML-400-C
KP-ML-450-A
Red: +
12~24VDC/AC
Black: -
Blue: N.O.
Door Status Output:
Green: COM.
1A/125VAC
Yellow: N.C.
Copyright © All Rights Reserved. P-MU-ML-450 Published: 2021.09.10
Mortise Mount Model Dimensions
KP-ML-450-B
Butt Splice (IDC) Connector
Using crimper or pliers and pressing the header
of connector down to even position.
ML-450M
KP-ML-450-C
Unti:mm

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ML-450 and is the answer not in the manual?

Questions and answers

Summary of Contents for ANXELL ML-450

  • Page 1 Butt Splice (IDC) Connector Using crimper or pliers and pressing the header of connector down to even position. Red: + 12~24VDC/AC Black: - Blue: N.O. Door Status Output: Green: COM. 1A/125VAC Yellow: N.C. Copyright © All Rights Reserved. P-MU-ML-450 Published: 2021.09.10...
  • Page 2 CL as Tighten the fixing lugs with Affix the strike plate. holes according to the templates. door leaf. screws. closely as possible. Unti:mm Surface Mount Model Dimensions ML-450MSMB Copyright All Rights Reserved. P-MU-ML-450 Published: 2021.09.10...
  • Page 3 Surface Mount Installation Blind Nut M6 x 25 Screw M6 x 25 Screw Blind Nut Unti:mm Glass Mount Model Dimensions ML-450MVGL Copyright All Rights Reserved. P-MU-ML-450 Published: 2021.09.10...
  • Page 4 3.The glass thickness should be 10~13 mm. The bracket can be adjusted to properly align the position of strike plate and lock body depending on the door gap ranging from 6 to 10 mm. Set Screws Frameless Glass Wall Set Screws Frameless Glass Door (10 to 13 mm thick) Copyright All Rights Reserved. P-MU-ML-450 Published: 2021.09.10...

This manual is also suitable for:

Ml-450mMl-450msmbMl-450mvglMl-400

Table of Contents