Operation; Storing, Transporting, Or Shipping - Desa Master B35CEB Owner's Manual

Table of Contents

Advertisement

OPERATION

WARNING: Review and understand the warnings
in the Safety Information Section. They are needed to
safely operate this heater. Follow all local codes
when using this heater.
TO START HEATER
1.
Follow all ventilation and safety information.
2.
Fill fuel tank with kerosene or No. 1 fuel oil.
3.
Attach fuel cap.
4.
Plug power cord of heater into standard 230 volt/50 hertz,
grounded (earthed) outlet. Use an extension cord if needed.
Use only a three-prong, grounded (earthed) extension cord.
Extension Cord Wire Size Requirements
Up to 30.5 meters (100 feet) long, use 1.0 mm
30.6 to 61 meters (101 to 200 feet) long, use 1.5 mm
conductor
Push ON/OFF switch to ON and heater should start. If heater does
not start, press flame-out control reset button (see Figures 5 and 6).
TO STOP HEATER
Push ON/OFF switch to OFF.
TO RESTART HEATER
1.
Wait 2 minutes after stopping heater.
2.
Repeat steps under To Start Heater.
ON/OFF
Switch
Flame-Out
Control
Reset Button
Figure 5 - Flame-Out Control Reset Button, 35/70,000 Btu/Hr
103615
Figure 6 - Flame-Out Control Reset Button, 100/150,000 Btu/Hr
STORING, TRANSPORTING,
2
(16 AWG) conductor
OR SHIPPING
2
(14 AWG)
Note: If shipping, transport companies require fuel tanks to be empty.
1. Drain fuel tank.
2. Replace drain plug if provided.
3. If any debris is noted in old fuel, add 1 or 2 quarts of clean
4. Replace fuel cap or drain plug. Properly dispose of old and
5. If storing, store heater in dry place. Make sure storage place is
IMPORTANT: Do not store kerosene over summer months for use
during next heating season. Using old fuel could damage heater.

STORING, TRANSPORTING, OR SHIPPING

ON/OFF
Switch
Note: Some models have drain plug on underside of fuel tank.
If so, remove drain plug to drain all fuel. If heater does not
have drain plug, drain fuel through fuel cap opening. Be sure
all fuel is removed.
kerosene to tank, stir, and drain again. This will prevent ex-
cess debris from clogging filters during future use.
dirty fuel. Check with local automotive service stations that
recycle oil.
free of dust and corrosive fumes.
OPERATION
5 5
Flame-Out Control
Reset Button

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Master b70cebMaster b100cebMaster b150ceb

Table of Contents