FUZRR ES3001 Manual

FUZRR ES3001 Manual

Soil resistivity meter

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ES3001 and is the answer not in the manual?

Questions and answers

Summary of Contents for FUZRR ES3001

  • Page 2: Table Of Contents

    CONTENT ……………………………………………2 I.Safety Precautions and Procedures ……………………………………………………………………3 II.Introduction ……………………………………………………………3 III. Rang and Accuracy ……………………………………………………4 IV.Technical Specifications …………………………………………………………………………6 V.Structure …………………………………………………………7 VI.Measuring Principle ……………………………………………………………………8 VII.Operation ……………………………………………………………………8 1. Switch on/off 2. Battery Voltage Check………………………………………………………9 3. Ground voltage measurement………………………………………………9 4.Wire resistance check………………………………………………………9 5.Four-wire Precision Test Grounding Resistance………………………10 6.Three-wire Test Grounding Resistance…………………………………13 7.Two-wire Easy Test Grounding Resistance……………………………13 8.Soil Resistivity Test……………………………………………………14...
  • Page 3: I.safety Precautions And Procedures

    I.Safety Precautions and Procedures Thank you for purchasing our company's Soil Resistivity Tester. Before using the instrument for the first time, in order to avoid possible electric shock or personal injury, please be sure to read and strictly observe the safety rules and precautions listed in this manual.
  • Page 4: Introduction

    it should be handled by a qualified organization. l The " " safety warning sign in the instrument and manual must be operated strictly in accordance with the contents of this manual. II.Introduction Soil Resistivity Tester also Known as Ground Resistance • Soil Resistivity Tester, Precision Ground Resistance Tester, etc., is a commonly used meter for measuring grounding resistance.
  • Page 5: Technical Specifications

    Grounding AC 0.00~100.0V ±2%rdg±3dgt 0.01V Voltage Remark: 1. Reference conditions: accuracy with Rh Rs < 100Ω。 Working conditions:Rh max=3kΩ+100R<50kΩ;Rs max=3kΩ+100R<50kΩ 2.Depends on the measurement accuracy of R,π=3.14, a:1 m~100m; IV.Technical Specifications Two three four-wire measure grounding resistance, soil Function resistivity; Ground voltage, AC voltage measurement Ambient 23℃±5℃,below 75%rh...
  • Page 6 Open circuit test AC 28V max voltage Electrode Can be set 1m ~ 100m spacing range fully automatic shifting 0.00Ω ~ 30.00kΩ Change gear fully automatic shifting 0.00 Ωm~9000kΩm Controllable gray screen backlight, suitable for use Backlight in dim places Display mode 4-bit large LCD display, gray screen backlight Measurement...
  • Page 7: Structure

    charging when battery voltage is low Automatic “APO” Indicates, automatic Shutdown After 15 Minutes Shutdown Standby: 40mA Max(Backlight off) Power Turn on backlight: about 43mA consumption measuring:75mA Max(Backlight off) Instrument: 2450(including battery) Weight Test lines:1300g Auxiliary grounding rod: 850g(4PCS) Working temperature and -10℃~40℃;below 80%rh humidity...
  • Page 8: Measuring Principle

    1. LCD 2. H interface:current pole 3. S interface:voltage pole 4. E interface:grounding pole 5. E interface: grounding electrode 6. Function button 7. DC charging 8. USB interface 9. Test button 10. Safety Alligator Clip 11.Test line 12. Grounding rob 13.
  • Page 9: Operation

    3.The working error (B) is the error within the rated operating conditions, which is calculated from the inherent error (A) and variation error (Ei) of the existing instrument.。 A: inherent error E2:Changes due to power supply voltage changes E3:Changes due to temperature changes E4:Changes due to disturbance voltage variations E5:Changes due to contact electrode resistance 4.Soil resistivity (ρ) is measured using the 4-pole method (Winner...
  • Page 10: Battery Voltage Check

    After powering on, if the LCD shows a low battery voltage symbol “ ”, it indicates that the battery is running low. Please charge it in time. The battery power is sufficient to ensure the accuracy of the measurement. When the battery power decreases, the power indicator bar decreases.
  • Page 11: 5.Four-Wire Precision Test Grounding Resistance

    instrument interface or poor contact; to avoid the error caused by the user to replace or lengthen the test line, the line resistance check function is specially designed to measure the low-value resistance more accurately. After connecting the test line and the meter, short the other end of all the test lines.
  • Page 12 spaced 5m ~ 20m, respectively, the S, H auxiliary grounding rod is buried deep into the ground in a straight line, connect the grounding test lines (black, green, yellow, and red) from the E, ES, S, and H interfaces of the meter to the ground electrode E under test, the auxiliary voltage electrode S, and the auxiliary current electrode H.
  • Page 13 R=r1∥r2∥r3∥r4∥r5∥r6∥…∥rn(r1…rnare all independent grounding points) R——meter readings, total grounding resistance of the entire grounding system; r1…rn——are all independent grounding points, and grounding bodies are not connected together under the ground; RH——ground resistance of auxiliary current pole H; RS——ground resistance of auxiliary voltage pole S; n——the number of independent grounding points, the more points, the smaller the R value.
  • Page 14: 6.Three-Wire Test Grounding Resistance

    6.Three-wire Test Grounding Resistance Three-wire test: As shown below, short-circuit the ES, E interface of the instrument, which is a three-wire test, instrument operation is the same as four-wire test.The three-wire test cannot eliminate the influence of the wire resistance on the measurement, nor can it eliminate the influence of the change of the contact resistance between the instrument and the test wire and the influence of the change between the test wire and the auxiliary grounding rod.
  • Page 15: 8.Soil Resistivity Test

    The simple two-wire method measures the grounding resistance. The instrument reading value is the sum of the grounding resistance of the measured grounding body and the grounding resistance of the commercial grounding body. That is: RE=RX+re And: RE is the meter reading value; RX is the grounding resistance value of the grounding body under test;...
  • Page 16 R——S-ES Resistance of soil between electrodes Four-pole method (Winner method):Connect the test leads as shown below. Note the spacing between the auxiliary grounding bars and the depth of burial,bury H, S, ES, and E auxiliary ground rods in the ground in a straight line, connect the grounding test leads (red, yellow, green, and black) from the H, S, ES, and E connectors of the instrument to the H, S, ES, and E auxiliary grounding rods under test.
  • Page 17: 9.Backlight Control

    9.Backlight Control After power on, press “ ” key to turn the backlight on or off, and the backlight function is suitable for dim places. The default backlight turns off every time you turn it on. 10.Alarm Setting After power on, short press “ ”...
  • Page 18: 12.Data Review/Delection

    12.Data Review/Delection After the power on or measurement is completed, press and hold the "MEM" button (more than 3 seconds) to enter the data review mode.The interface corresponding to the stored data interface and the stored data group number flash alternately.Press " "...
  • Page 19: Battery Instructions

    VIII. Battery Instructions The instrument is powered by a 6V 4.5AH lead-acid battery. When the battery power is reduced, the power indicator bar is reduced. When the voltage drops to 5V, the battery symbol “ ” is displayed. Please charge in time. Low voltage affects the measurement accuracy.
  • Page 20 The contents of this user manual cannot be used as a reason to use the product for special purposes. The company is not responsible for other losses caused by use. The company reserves the right to modify the contents of the user manual. If there is any change, it will not be notified.

Table of Contents