COOKER
Door hasp will not engage:
1. Door loose and requires new bushings.
2. Hasp requires adjustment by adding or removing of washers under hasp.
Handwheel hard to turn:
1. Foreign matter on thrust screw or lack of lubricant.
2. Thrust screw bent or worn.
Door gasket leaks:
1. Gasket screw loose.
2. Gasket damaged or at end of useful life.
3. Door loose and not aligned correctly.
4. Gasket plate installed incorrectly.
5. Handwheel binding so that not enough pressure to seal door.
Water accumulates in compartments:
1. Appliance not levelled properly.
2. Compartment screen plugged.
3. Exhaust valve plugged or defective.
4. Exhaust drain line plugged.
Compartment pressurized at end of cooking cycle:
1. Exhaust valve plugged or defective.
PART NUMBER 10045R1