Download Print this page

Rear Panel - Mechanics & Electronics ME750-FD Operating Manual

4/6m linear amplifier 2xgi7bt

Advertisement

3/b REAR PANEL
1. 230V
Power cord fit for standard 230V-50/60Hz mains. The colour of the protective earth is
green/yellow.
2. FUSE1-2
Main fuses, 230V max. 10A.
3. FUSE3
HV fuse. 1A.
4. FUSE4
Fuse for the 18V AC. Value range 1.6A.
5. FAN 1
Cooling fan for the main transformer. 12V - 0.2A DC.
6. FAN 2
Cooling fan for the power valves. 12 - 18V/ 0.3A DC, or 230V AC 18W.
7. PTT
Connection for PTT RCA. The relays are closed by earth connection. Low voltage, low current
entry. Fit for open collector control as well.
8. INPUT
Input connection for the driver TCVR. 50 Ohm ("N" connectors on both bands,the 6m input is
on the center position.
9. OUTPUT
Aerial connection. 50 Ohm Common ant connector on both bands.(4&6m)
10. GND
Ground connection
11. ALC
Option.
.
8