Page 2
Read manual in its entirety before using the unit and save manual for future reference. EPL-100BT-12V-G2 EPL-125BT-12V-G2 EPL-200BT-12V-G2 Enerdrive B-TEC G2 Manual (Rev. 2.1) April 2020 Support Contact Information Warranty Returns: Reply Paid 8786, Wynnum Plaza, QLD 4178 Email: support@enerdrive.com.au Page 2 Enerdrive B-TEC G2 Manual (Rev.
Step 3. Fully charge the battery and it is ready for use. *Note: The above is a “Quick Start” guide, detailed information follows. Page 4 Enerdrive B-TEC G2 Manual (Rev. 2.1)
Section 2 - Charging Lithium batteries need to be charged slightly differently to other batteries. To ensure they live a long life and provide maximum capacity, you must use a charger with a lithium setting - this includes: AC Chargers DC to DC Chargers Solar Controllers If your charger allows, set the charge voltage from 14.0 -14.6 Volts and Float 13.5 - 13.6 Volts.
Section 3 - Discharging (using the battery) The Enerdrive B-TEC Lithium Battery can deliver a maximum of 100 Amps for the 100 & 125Ah battery and 200 Amps for the 200Ah battery for 30 minutes due to the high power, high quality Battery Management System (BMS) and prismatic Lithium cells inside the battery.
It is recommended that Lithium batteries not be discharged below 20% State of Charge or the battery life may be shortened. As an added layer of protection, the Enerdrive B-TEC Lithium Battery also has a built-in low voltage Section 5 - Restarting Your Battery.
By continuously tripping the low voltage disconnect of the battery you may cause damage to sensitive electronic equipment that is attached to the battery. I.E. battery chargers, solar controllers, inverters, stereo equipment etc - all of which are not covered under the battery warranty. Page 8 Enerdrive B-TEC G2 Manual (Rev. 2.1)
Section 6 - Using the Smart Phone Battery Monitor The Enerdrive B-TEC Lithium Battery incorporates a Smart Phone Monitoring system. By downloading the Android™ or Apple® app to your smart phone or tablet, you can monitor the following information: Battery Capacity...
The battery has a low voltage disconnect incorporated for self protection. If the battery is drawn down to the internal low voltage disconnect set point (≤2.8v per cell) the battery will disconnect. Page 10 Enerdrive B-TEC G2 Manual (Rev. 2.1)
Section 8 - FAQ Can I parallel B-TEC batteries? The short answer is yes. The long answer is - if you are drawing large currents, the maximum current delivered will be limited to the maximum instantaneous discharge capacity of one battery. for the 100 & 125Ah batteries this is 100 Amps and for the 200Ah battery, 200 Amps.
Page 12
Can I install the B-TEC battery in a wet area? It is not recommended - the best environment is a dry, cool, well ventilated area. Can I install the B-TEC battery on its side or end? Page 12 Enerdrive B-TEC G2 Manual (Rev. 2.1)
fitness for a particular purpose on this unit is limited in duration to the duration of this warranty. Enerdrive Pty Ltd warrants it B-TEC Lithium Battery (hereafter referred to as “Battery”) to be free of defects in material and workmanship for the following Applicable Warranty Period: 2 years for;...
Page 15
Limitations This warranty does not cover damage or defects resulting from normal wear and tear (including chips, scratches, abrasions, discolouration or fading due to usage or exposure to sunlight), accidents, damage during shipping to our service facility, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and maintenance, acts of god, re and ood.