Plymovent OS-4 WRK Product User Manual

Wireless retrofit kit

Advertisement

Quick Links

OS-4 WRK
Wireless Retrofit Kit
Thank you for buying a Plymovent product. Before you unpack and put it into operation please read this
This manual should be handed over and kept by the service department
Sales of ce
Plymovent AB
Kopparbergsgatan 2
SE-214 44 MALMÖ
SWEDEN
Tel: +46 40 30 31 30
Fax: +46 40 30 31 40
info@plymovent.se
MAN_WRK_EN
5757-1011-100413:Rev1.1
product manual carefully, and follow the instructions.
after the installation.
England
Plymovent Ltd
Marley Way, Southam Road
Banbury, OX16 2RA, England
Tel: + 44 1295 25 93 11
Fax: + 44 1295 27 17 50
info@plymovent.co.uk
PRODUCT USER MANUAL
contents
1. Safety .................................................................................. 2
2. Important safety instruction ........................................ 3
3. Introduction ..................................................................... 3
4. System components ...................................................... 4
5. Installation......................................................................4-5
6. Reciever programming ................................................... 6
6. 1 Overview........................................................................6
6.2 Installation and Start-up...............................................7
6.3 System Test Mode.......................................................10
6.4 Operation.....................................................................11
6.5 Connect input / Output Cabling..............................11
6.6 Mount the Receiver.................................................... 12
6.7 Specifications................................................................12
6.8 Receiver Warrantee....................................................12
7. Wire Diagram ................................................................13
8. Operation .......................................................................14
9. Warrenty ........................................................................14
10. Maintenance .................................................................14
11. Disposal ........................................................................14
12. CE Declaration.............................................................14
Canada
Plymovent Inc
24- 1200 Aerowood Dr
Mississauga, On L4W 2S7, Canada
Tel: +1 (905) 564-4748
Fax: +1 (905) 564-4609
info@plymovent.ca
USA
Plymovent Corp.
115 Melrich Road
Cranbury, New Jersey 08512, USA
Tel. + 1 609 395 3500
Fax. + 1 609 655 0919
info@plymovent.com
© Plymovent AB reserves the right to make design changes.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OS-4 WRK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Plymovent OS-4 WRK

  • Page 1: Table Of Contents

    11. Disposal ................14 12. CE Declaration.............14 Thank you for buying a Plymovent product. Before you unpack and put it into operation please read this product manual carefully, and follow the instructions. This manual should be handed over and kept by the service department after the installation.
  • Page 2: Safety

    SAFETY WARNING Do not attempt installation of this unit unless you General are familiar with the necessary tools, equipment, The manufacturer does not accept any liability for damage to utility connections and potential hazards. Installation the product or personal injury caused by ignoring of the safety should be performed only by a qualified service instructions in this manual, or by negligence during installation, provider.
  • Page 3: Important Safety Instruction

    To reduce the risk of electric shock, fire and injury to persons: OS-4 WRK (Reciever assembly), the OS-4 WRK-T (Transmit- • Do not use the OS-4 WRK in wet or damp locations. ter). • Do not use the OS-4 WRK outdoors. The OS-4 WRK kit allows for a pressure switch to be placed PREFACE on a moving trolley without the need for hard wiring back to the OS-4 box. The WRK-R is capable of monitoring up to Using this manual 16 OS-4 WRK-T sensors simultaneously.
  • Page 4: System Components

    2. Add a hole (if required) to the OS-4 enclosure. 3. Run the wire from the OS-4 WRK-R into the OS-4 panel. Cut the wires to the proper length, strip ends, insert into proper leads, tighten wire holders, tuck away or wire tie and lose wire.
  • Page 5: Installation

    When installing a system calling for a wireless system to be installed, it is easiest to install the complete system prior to the installation of the OS-4 WRK-T transmitter. To install the pressure sensor and Os-4 WRK-T to the trolley: 1. Program Transmitter before installation (instruction or later in manual) 2.
  • Page 6: Reciever Programming

    4216MR EchoStream® Receiver 2 Installation and Startup allation and Operation Manual - 05395G 2.1 Connect Power Cabling RECEIVER/TRAMSMITTER PROGRAMMING Before beginning startup, you will need to connect power power to the receiver: verview 1. Overview Caution: Graded application must use the cabling knocko nics EchoStream technology is designed to minimize dead spots in transmission housing.
  • Page 7: Installation And Startup

    RECEIVER/TRAMSMITTER PROGRAMMING 1.4 EE4216MR LEDs NOTE: The default level 2 authorized user password is NOTE: 3446. Note: The EE4216MR operation LEDs are only visible when the cover is removed. Level 3 authorized installer access: A level 3 authorized installer has the ability to access all Output LED: Lights when any output is active.
  • Page 8 RECEIVER/TRAMSMITTER PROGRAMMING press the Enter button to select a point. and Down buttons to select; press the Enter button to select. • TX REGISTR’D displays if a transmitter or repeater is Inactive Out: Maps transmitter/repeater inactivity fault output. Use the Up/Down buttons to scroll through the output currently registered to this point; TX NOT REGSTR’D displays if no transmitter is registered to this point. numbers.
  • Page 9 RECEIVER/TRAMSMITTER PROGRAMMING To select a space, press Enter without selecting a digit. numbers. Choosing - - will disable low battery output. Press Enter to select the output to use for this transmit ter/repeater’s low battery transmission. NOTE: Low Battery Output Type Selects the output type for the If you do not use all eight characters, you must enter low battery condition.
  • Page 10: System Test Mode

    RECEIVER/TRAMSMITTER PROGRAMMING options. The CLEAR LANG option resets the language to the NOTE: default and exits the INSTALL & SERVICE menu. Inovonics recommends an LV of four for most instal- 3. Press Enter to select language. lations. For CENELEC, Grade 2 installations, an LV of 4. When LANGUAGE SELECTED displays, press Enter to 10 or greater is required. return to the INSTALL & SERVICE menu.
  • Page 11: Operation

    RECEIVER/TRAMSMITTER PROGRAMMING NOTE: NOTE: No output will be displayed if the event is mapped An activation from any condition of a multiple con- to a null output. dition transmitter will satisfy the test requirement for the entire transmitter. For example, pressing any 4.3 Alarms and Faults button on an EN1236 three-condition pendant will Points in alarm are immediately displayed as ALARM, with the satisfy the test requirement for the entire point number.
  • Page 12: Mount The Receiver

    RECEIVER/TRAMSMITTER PROGRAMMING 6.6 Mount the Receiver 6.8 Warranty/Disclaimer CAUTION: CAUTION: Mount the receiver in a location removed from Changes or modifications to this unit not expressly metal. Metal objects (duct work, wire mesh screens, approved by Inovonics Wireless Corporation may boxes) will reduce RF range. void the installer’s authority to operate the equip- ment as well as the product warranty.
  • Page 13: Wire Diagram

    WIRE DIAGRAM PUM_WRK_100217_EN 13/14...
  • Page 14: Operation

    11. DISPOSAL 8. OPERATION Once the OS-4 WRK-Receiver is installed and all OS-4 WRK- After life of the product, dispose it of in accordance with state Transmitters are installed the OS-4 power can be turned back or local regulations. on. It is recommended to test the system at each drop by...

Table of Contents