Rodenstock H Series Operator's Manual

Rodenstock H Series Operator's Manual

Slit lamp

Advertisement

Quick Links

RSL 5000
SLIT LAMP
OPERATOR MANUAL
H Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Rodenstock H Series

  • Page 1 RSL 5000 SLIT LAMP OPERATOR MANUAL H Series...
  • Page 2: Table Of Contents

    SLIT LAMP RSL 5000 by RODENSTOCK CONTENTS INDICATIONS FOR USE ..................3 SAFETY ......................... 3 PHOTOTOXICITY ..........................3 WARNINGS AND CAUTIONS ......................4 CONTRAINDICATION ........................5 CLEANING AND DISINFECTION INSTRUCTIONS ............ 5 NAMES OF CONTROLS AND COMPONENTS ............6 ASSEMBLY ......................7 ILLUMINATION TOWER ASSEMBLY PROCEDURE ................8 CABLE ATTACHMENT PROCEDURE ....................9...
  • Page 3: Indications For Use

    This Rodenstock Slit Lamp can either be mounted onto a custom table top supplied by Keep dry Conformité Européene Rodenstock or can be mounted on a third parties table top (refraction unit) by suitably trained technicians. Fragile Type B applied part The Rodenstock Slit Lamp consists of 4 assemblies;...
  • Page 4: Warnings And Cautions

    Electrical equipment can be affected by electromagnetic interference. If this occurs whilst or misuse. using this equipment, switch the unit off and reposition. • Check your Rodenstock product for signs of transport / storage damage prior to use. • Do not touch accessible connectors and the patient simultaneously. •...
  • Page 5: Names Of Controls And Components

    21. Microscope arm locking knob 5. ASSEMBLY Your Rodenstock Slit Lamp has been designed to fi t on to an electric insulated medical table base or on to an electric insulated and fi re resistant medical table top, e.g. a Refraction Stand or Combi Unit.
  • Page 6: Illumination Tower Assembly Procedure

    The Refraction Stand, Combi Unit or table leg must be IEC 60601-1 compliant. If you are fi tting or have fi tted your Slit Lamp to a medical or Rodenstock table leg / base ensure it is situated on a fi rm and level fl oor.
  • Page 7: Fitting Applanation Tonometers, T Type And R Types

    SLIT LAMP RSL 5000 by RODENSTOCK SLIT LAMP RSL 5000 by RODENSTOCK 6. INSTRUCTIONS FOR USE Only a hospital grade 3-conductor electrical power supply cable must be 6.1 SETTING THE BINOCULARS used. For USA and Canada: Detachable power supply cord set, UL listed, type SJE, SJT or SJO, 3-conductor, not smaller than 18 AWG.
  • Page 8: Preparing The Patient And Using The Slit Lamp

    Shut down after every use. In case the dust cover is used: risk of Rodenstock recommends the use of disposable hygienic chinrest tissues overheating. on the chinrest before the patients place their chin on it.
  • Page 9: Routine Maintenance

    LED life. accordance with these manufacturer’s instructions. In the unlikely event of an LED failure please contact Rodenstock or your local distributor for There are no user serviceable parts in this instrument. Any servicing guidance on the replacement procedure.
  • Page 10: Electromagnetic Immunity

    = 0%; 1 cycle = 0%; 1 cycle should be considered. If the measured field strength in the location in which the Rodenstock Slit Lamp is used operations during power mains exceeds the applicable RF compliance level above, the Rodenstock Slit Lamp should be observed to verify normal IEC 61000-4-11 = 70%;...
  • Page 11: Technical Specifications

    SLIT LAMP RSL 5000 by RODENSTOCK SLIT LAMP RSL 5000 by RODENSTOCK as recommended below, according to the maximum output power of the communications Filters Clear; red free; neutral density; diffuser; blue; IR heat equipment. absorbing filter permanently installed Slit angle +/- 90°...
  • Page 12: Accessories And Spares

    SLIT LAMP RSL 5000 by RODENSTOCK SLIT LAMP RSL 5000 by RODENSTOCK Environmental Conditions: Item Part Number DSL Accessory Kit Packaging 3020-P-5221 1060 hPa °C DSL Digital Background Illum.Assy 3020-P-5039 DSL Digital Backlight Filters 3020-P-7054 °C 800 hPa DSL DIGITAL LEFT/RIGHT LABEL...
  • Page 13 SL4 4AA UK Freephone 0800 521251 Tel +44 (0) 1753 857177 Fax +44 (0) 1753 827145 SUPPLIER Rodenstock Instruments Business Unit of Tomey GmbH Wiesbadener Straße 21 90427 Nürnberg Germany Tel +49 9131 777 1 777 Fax +49 9131 777 1 20 Visiometrics, S.

This manual is also suitable for:

Rsl 5000