  • Page 1 INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS K1-9026 LEVER MONOBASIN WITH VOLUME CONTROL, WITH P.U.W.
  • Page 2: Table Of Contents

    Contents Dimensions Instal ation Procedure Parts List Fault Finder Safety Tips, Care and Maintenance Guarantee...
  • Page 3: Dimensions

    Dimensions in Inches (& Millimetres) 6 5/8" (168.5mm) 3 3/8" (85mm) Ø1 5/8" (Ø41.5mm) Ø1 7/8" (Ø48mm) Ø2 1/8" (Ø56mm) Ø1 1/4" (Ø31.75mm) 12"MAX (305mm MAX) Whilst every effort is made to ensure accuracy, design and dimensions are subject to change without notice as part of the company’s product development process.
  • Page 4: Instal Ation Procedure

    Installation Procedure Steps 1-2 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. Shut off main water supply before installation. Put the base under the bottom of faucet. Attach the fixing bolts to the faucet. Attach the flexible hoses to the faucet.
  • Page 5 Installation Procedure Steps 3-4 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. Shut off main water supply before installation. Install Pop-up rod. Install faucet through deck hole. From underneath the sink, install washers and nut.
  • Page 6 Installation Procedure Steps 5-6 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. Shut off main water supply before installation. Install the Pop-up assembly. After installing faucet, remove aerator and open the hot and cold supplies.
  • Page 7: Parts List

    Parts List Exploded view Handle (069759-51) Escutcheon (034770) Washer (013715) Shroud (103319) O-ring (048031N) Adaptor (039807) Adjusting ring (104233) Flexible hose (105652W) Fixing bolt (017820) Cartridge (507348N) Pop-up sub-assembly (556781) Pop-up rod (125322) Spout assembly (061943W) Pipes assembly (064297W) Pop-up knob (124367) Allen key (031003) O-ring (004001N) Set screw (075018)
  • Page 8: Fault Finder

    Fault Finder Fault Cause Rectification Leaks around handle. Shroud or adjusting ring has come Tighten the shroud or adjusting ring. loose. Leaks around the base of spout. Gasket is misfitted or damaged. Check for gasket placement. Aerator leaks or has an inconsistent Aerator is dirty or misfitted.
  • Page 9: Safety Tips, Care And Maintenance

    Safety Tips, Care and Maintenance Safety Tips If you are soldering during faucet installation,remove cartridges, seats, gaskets and washers prior to applying flame, otherwise you will void the warranty. Cover drain openings to avoid losing small parts. When cutting or soldering pipe, use safety glasses to protect your eyes. Important Points Prior to beginning installation.
  • Page 10: Guarantee

    Not Covered by this Guarantee Damage or defects arising from incorrect installation, improper use or lack of maintenance. Installed product damaged in transit Consequential loss, damage or product removal and installation costs. Lefroy Brooks is not responsible for any on site labour charges.
  • Page 11 TELEPHONE: 718-302-5292. FAX: 718-302-4177 The use of trademarks, product design and artwork is subject to licence or agreement with Christo A. Lefroy Brooks. The design registrations, trademark registrations and copyrights are protected by law and the use or reproduction outside the terms of an agreement is prohibited.