Liquid Level Alarm
4.3.1
Program the Indoor Display
Disconnect power from the indoor alarm display.
Open the back cover of the display and move the
jumpers for the code and the channel. See FIG 1.
Replace the cover.
Hold the Silence button down while connecting
power. The LED will turn on bright red indicating that
programming mode is entered. Release the button
and the LED will go out.
Within 5 seconds, press the button down until the
LED turns on bright red. Perform this 1 to 6 times to
select the number of Flashes.
Wait for 5 seconds, and the LED will fl ash back
what has been programmed.After another 5 second
delay it will fl ash once or twice confi rming the
channel setting. The display will then go into normal
operation.
4.3.2
Program the outdoor transmitter
Disconnect the power from the outdoor transmitter
by removing a battery. Discharge the capacitance by
using a short length of wire to short out the red and
black wires of the battery holder.
Move the installer code and channel jumpers to your
selected position. See FIG 3.
Hold down the push-button switch while installing the
last battery. The LED will turn on bright red indicating
that programming mode is entered. Release the
push-button and the LED will go out.
Within 5 seconds, press the button down until the
LED turns on bright red. Perform this 1 to 6 times to
select the number of Flashes.
Wait for 5 seconds, and the LED will fl ash back what
has been programmed.After another 5 second delay
it will fl ash once or twice confi rming the channel
setting. The transmitter will then go into normal
operation.