Sentry
Liquid Level Alarm
4.3.1
Program the Indoor Display
•
Disconnect power from the indoor alarm display.
•
Open the back cover of the display and move the
jumpers for the code and the channel. See FIG 1.
Replace the cover.
•
Hold the Silence button down while connecting
power. The LED will turn on bright red indicating that
programming mode is entered. Release the button
and the LED will go out.
•
Within 5 seconds, press the button down until the
LED turns on bright red. Perform this 1 to 6 times to
select the number of Flashes.
•
Wait for 5 seconds, and the LED will fl ash back
what has been programmed.After another 5 second
delay it will fl ash once or twice confi rming the
channel setting. The display will then go into normal
operation.
4.3.2
Program the outdoor transmitter
•
Disconnect the power from the outdoor transmitter
by removing a battery. Discharge the capacitance by
using a short length of wire to short out the red and
black wires of the battery holder.
•
Move the installer code and channel jumpers to your
selected position. See FIG 3.
•
Hold down the push-button switch while installing the
last battery. The LED will turn on bright red indicating
that programming mode is entered. Release the
push-button and the LED will go out.
•
Within 5 seconds, press the button down until the
LED turns on bright red. Perform this 1 to 6 times to
select the number of Flashes.
•
Wait for 5 seconds, and the LED will fl ash back what
has been programmed.After another 5 second delay
it will fl ash once or twice confi rming the channel
setting. The transmitter will then go into normal
operation.
Page 14