This technical description contains important information for the start up and use of the MTX-Gateway modems. Read it carefully before you start working with the MTX-Gateway modems. The warranty will be void should damage occur due to non-compliance with these instructions for use. We cannot accept any responsibility for consequential loss.
DESCRIPTION The MTX-Gateway is designed to be driven by the TQMa28 module and offers PC core functionalities and standard interfaces. This user guide provides information about the components, features, connectors and signals available on the MTX-Gateway. 1. Product Label The label fixed to the bottom of a MTX devicel comprises the following information: 1.
Illustration 1: MTX-Gateway block diagram 1.2 Technical Data Electronics The interfaces and system components listed in the following are implemented on the MTX-Gateway. Due to the fact that the board can be installed in a casing, the interfaces are divided into external and internal interfaces.
1.1 Function Specification 1.1.1 VGA The LCD interface of the TQMa28 drives the Analog Devices ADV7125 to offer a VGA output on the MTX- Gateway. DB15 (J4) TQMa28 ADV7125 (U10) DB15 (J5) Type of media: Interface on module: RGB, 18bit Signal Characteristic: Compatible with RS-343A and RS-170 1.1.2 USB OTG...
Top entry Mini USB B MOLEX: 47590-0001 Right angle Micro USB AB OUPIIN: 8968-A04C00RWA Right angle USB A 1.1.3 Ethernet The MTX-Gateway directly drives the Ethernet 1 interface. The SMSC LAN8720Ai is used as a PHY. RJ45 (Ue3/Ue2) TQMa28 LAN8720Ai (Ue1)
1.1.4 RS232/485/422 The AUART0 of the TQMa28 drives the RS232/485/422 interface on the MTX-Gateway. The Maxim MAX3160 is used as a transceiver. DB15 (J6/J16) MAX3160 TQMa28 (Uu3) Pluggable terminal (J11) In addition, two signals are used in order to configure the Maxim transceiver in one of its operational...
1.1.5 RS232_1 The AUART3 interface of the TQMA28 drives the RS232 interface of the MTX-Gateway by default. The Maxim MAX3221EEAE is used as a driver. DB15 (J6/J16) MAX3221 TQMa28 (Uu1) Pluggable terminal (J12) Transfer rate: Up to 250Kbit/s Interface on module:...
TYPE REMARK TXD1 Transmit Data RXD1 Receive Data Ground 1.1.6 RS232_2 The AUART1 interface of the TQMA28 drives the RS232 interface of the MTX-Gateway by default. The Maxim MAX3221EEAE is used as a driver. DB15 (J6/J16) MAX3221 TQMa28 (Uu2) Pluggable...
1.1.7 CAN The CAN 0 port of the TQMA28 directly drives the interface on the MTX-Gateway. The NXP TJA1051T/3 is used as a CAN transceiver. DB15 (J6/J16) MAX3221 TQMa28 (U3) Pluggable terminal (J12) Transfer rate: Up to 1Mbit/s Interface on module: CAN_0 Signal characteristic: Compatible with the ISO-11898 standard (CAN 2.0B)
Pluggable terminal pinout (J12): SIGNAL TYPE REMARK CANH CAN High-Level I/O CANL CAN Low-Level I/O 1.1.8 1-Wire A 1-Wire interface is available on the MTX-Gateway via the Maxim DS2482-100 I2C chip. DB15 (J6/J16) DS2482-100 TQMa28 (U2) Pluggable terminal (J13) Transfer rate:...
1.1.9 Relays There are four different relay configurations supported by the MTX-Gateway. The device must be ordered with its required corresponding relay. 2 coil latching Option A Up to 2 Option B TQMa28 Up to 2 Option C 1x LY relay...
1.1.10 Power Supply For protective and EMC reasons the supply input of the MTX-Gateway is designed very robustly. PLUG CONNECTOR AC-DC Vout 90-230VAC/ Fuse 0.5A Out: 15VDC 15VDC 120-370VDC (J7) SWITCHING REGULATOR 5V OPTION A Line Filter OPTION B SWITCHING REGULATOR 3.3V...
MAX. UNIT AC Input Voltage Power consumption 2. Internal Interfaces 2.1 TQMa28 The core of the MTX-GTW is the TQ Components TQMa28 module. The following table shows the key features of this module. FEATURE DESCRIPTION Processor Freescale iMX287 @ 454MHz...
2.2 miniPCIe Card A miniPCIe Card slot (also known as Mini PCI Express, Mini PCIe and Mini PCI-E) is available on the MTX- Gateway. The following table shows the buses supported by the device: REMARK USB 2.0 UIM signals for GSM and WCDMA applications...
2.3 WiFi The MTX-Gateway can be ordered with an integrated Bluegiga WF111 Wi-Fi module. The following table shows the key features of this module. FEATURE REMARK IEEE 802.11 b/g/n Single 2.4GHz band. Symbol rate up to 7.2Mbps Encryption WEP, WPA and WPA2...
3. User Interfaces 3.1 Status LED The MTX-Gateway has six LEDs to inform the user about different status conditions. The following table shows the different LED indications. STATUS REMARK Connected to miniPCIe Card WWLAN# signal. DLp1 On when 5VCC is good...
3.2 DIP Switches The MTX-Gateway has two Dip-Switches for configuration purposes. The following tables show information about the signals connected to each Dip Switch. SW1: SIGNAL REMARK LCD_D04 LCD_D03 LCD_D02 Booting Configuration Signals LCD_D01 Check TQMa28 User Guide for more information...
TQMa28 EEPROM – M24C46 0x50 4.3 RTC A DS1339U RTC module is on the MTX-Gateway board. The RTC is supplied by a super capacitor in order to maintain the information should the main supply be removed. I2C BUS POSITION DEVICE...
2. General Precautions The MTX-Gateway has an IP65 enclosure which protects itself again dust, external impact and contact. However, as the MTX-Gateway PCB can be bought as a standalone product, the following points must be considered: 2.1 Protection Against External Effects The MTX-Gateway PCB is not protected against dust, external impact and contact (IP00).
2. General Precautions The MTX-Gateway terminal as a standalone item is designed for indoor use only. For outdoor use it must be integrated into a weatherproof enclosure. Do not exceed the environmental and electrical limits as specified in “Technical Data”.
20cm from the body. In all other configurations the user is responsible for meeting the local SAR regulations. Users of the MTX-Gateway wireless modem device are responsible for ensuring that they meet the SAR regulatory requirements of the countries in which they intend to operate the device and that their documentation contains the relevant SAR declaration, certification information and user guidance as appropriate.
Wireless modem devices may affect the operation of cardiac pacemakers, hearing aids and certain other implanted equipment. If a minimum distance of 15 cm (6 inches) is maintained between the MTX- Gateway modem radiating antenna and a pacemaker, the risk of interference is limited. If the user’s application is likely to be situated in the vicinity of personnel, a suitable warning should be contained in the equipment manual to this effect.
CONFORMITY ASSESSMENT RED Declaration of Conformity (DoC) Unique identification of this DoC: MTX-Gateway RED DoC MATRIX ELECTRÓNICA S.L., C/ Alejandro Sanchez 109, 28019 Madrid, Spain declare under our sole responsibility that the products MTX-Gateway family MTX-Gateway 199802101 MTX-Gateway-3G (EHS6) 199802121...
SVN: 08 NAPRD.03 Version: GSM Test: 5.15/OTA Performance Test: 5.15 2. FCC Compliant MTX-Gateway 3G and any variants contain FCC ID: QIPEHS6. The FCC Equipment Authorization Certification for the EHS6 Module is listed under the FCC identifier QIPEHS6. Industry Canada Certification Number: 7830A-EHS6 granted to Gemalto M2M GmbH.
The MTX-Gateway device was not observed to cause any adverse problems to the AT&T network when activated and used in the lab. The MTX-3G-JAVA is certified for both CS and PS services (as applicable). Any change to the mode of operation invalidates the AT&T Certification.
MATRIX ELECTRÓNICA S.L., C/ Alejandro Sanchez 109, 28019 Madrid, Spain 1. Estándares de homologación europea Declaramos bajo nuestra responsabilidad que los productos MTX-Gateway que contienen un modulo celular Cinterion EHS6 (tipo L30960-N2950-A100), al cual se refiere esta declaración, están están conformes con la Directiva RED 2014/53/EU.
2. Aprobación PTCRB PTCRB es un aprobado regional necesario en el mercado norteamericano. MTX-Gateway tiene la certificación PTCRB: Solicitud #: 39216 Fabricante: Matrix Electronica Modelo#: MTX-Gateway Tecnologías y bandas de frecuencias: GSM 850/900/1800/1900, UMTS FDD: Band I/Band II/Band V/ Band VIII...
3. Conformidad FCC MTX-Gateway y todas sus variantes contienen el FCC ID: QIPEHS6. El Certificado de Autorización de Equipo de la FCC para el módulo EHS6 está listado con el identificador FCC QIPEHS6 Número de Certificación de Industria en Canadá: 7830A-EHS6 asignado a Gemalto M2M GmbH.
• Prueba de selección de red El dispositivo MTX-Gateway no ha evidenciado ni causado ningún tipo de problema en la red de AT&T cuando ha sido activado y utilizado en el laboratorio. El MTX-3G-JAVA está certificado para servicios CS y PS.
INFORMATION 1. Directives and Standards The MTX-Gateway modem has been designed to comply with the directives and standards listed below. It is the responsibility of the application manufacturer to ensure compliance of the final product with all provisions of the applicable directives and standards, as well as with the technical specifications provided in this document.