Nittan EL.MO. Spa MCMAS5 Technical Manual

Conventional detectors input module for as protocol loop

Advertisement

Quick Links

www.acornfiresecurity.com
MCMAS5
Conventional detectors
input module
for AS protocol loop
090010924
www.acornfiresecurity.com

Advertisement

loading

Summary of Contents for Nittan EL.MO. Spa MCMAS5

  • Page 1 www.acornfiresecurity.com MCMAS5 Conventional detectors input module for AS protocol loop 090010924 www.acornfiresecurity.com...
  • Page 2 www.acornfiresecurity.com MCMAS5 - TECHNICAL MANUAL - 090010924 FOREWORD FOR THE INSTALLER: Please follow carefully the specifications relative to electric and security systems realization further to the manufacturer’s prescriptions indicated in the manual provided. Provide the user the necessary indication for use and system’s limitations, specifying that there exist precise specifications and different safety performances levels that should be proportioned to the user needs.
  • Page 3: General

    www.acornfiresecurity.com 090010924 - TECHNICAL MANUAL - MCMAS5 1. GENERAL EL.MO.’s MCMAS5 is the new conventional detectors input module for AS protocol analogic loop systems. Born from the experience and from the studies of our R&D team, it can boast several strengths: •...
  • Page 4 www.acornfiresecurity.com MCMAS5 - TECHNICAL MANUAL - 090010924 Rotary switches Reset button Jumpers Pins Terminal board Relay commanded AS Protocol loop. devices, if present Connect the cable Detector line: shields togheter. refer to the following diagrams Power supply unit, PSU fault output +24 V if present (drop-out alarm relay)
  • Page 5: Unplugging And Plugging Back The Terminal Board

    www.acornfiresecurity.com 090010924 - TECHNICAL MANUAL - MCMAS5 Connect the cable shields of the loop to the one of the L/C line Fault relay 560 Ω, ¼ W 3650 Ω, 1%, ¼ W Alarm relay Linear smoke detector Connect the screen to an insulated terminal 560 Ω...
  • Page 6: Jumpers Settings

    www.acornfiresecurity.com MCMAS5 - TECHNICAL MANUAL - 090010924 4.4 Jumpers settings Each jumper (pic. 1a) is a plastic cap with a protruding tab allowing for an easy removal and containing a conductive element on the inside. The conductive element realizes an electric bridge between two of the three vertically aligned pins protruding from the board. Connecting the lower pins activates the function described below the jumpers’...
  • Page 7: Table Of Contents

    www.acornfiresecurity.com 090010924 - TECHNICAL MANUAL - MCMAS5 5. PROGRAMMING • Following the instructions in the control unit programming manual, set the activation of MCMAS5’s relay output whenever an alarm signal comes from the module’s detector line. This setting is mandatory for every detector type, but give special attention if it is used to power off a linear smoke detector in order to reset it (pic.