Make sure that all cables and connectors are properly connected. Do not operate this equipment in the potentially explosive environment. Do not operate the generator in area where flammable or explosive gases stored PTS-G5K13M PTS Co., Ltd.
Page 4
All warnings and cautions mentioned in the Manual would advance warning of potential hazards to prevent accidents (see following safety symbols). Thank you for using our RF Generator. PTS and our employees would always be there to manage customer's request. As much as possible, we will do our best to improve customer’s service quality.
Page 5
It tells you potential activities to reduce serious damage This sign is physical damage due to high voltage. It warns the product weights more than 20kg, and tells to Use Lifting Aids with Proper Lifting Techniques to ask for help. PTS-G5K13M PTS Co., Ltd.
Page 6
This symbol is asked to refer to the Manual for reliable equipment operation. This symbol indicates the position where one has to connect Ground for reliable equipment operation. PTS-G5K13M PTS Co., Ltd.
① Fill out the front and rear of the cooling fan blower of the product smoothly. ② Make a space and exhaust fan from front(>15cm), side(>15cm), rear (>30cm) ③ Set up exhaust fan in the rack more than6㎥/min. 3. Dimensions PTS-G5K13M PTS Co., Ltd.
RF-ON LED Light turns on when RF-On is on. ALARM Light turns on when there is a warning. TEMP Light turns on when high temperature reading is there. COAX Light up when COAX cover removed. PLUSE PTS-G5K13M PTS Co., Ltd.
Page 11
Circuit protector Main Switch ③ PTS-G5K13M PTS Co., Ltd.
Page 12
④ RF output connector ( 'HN' Type Female) & Connector cover ⑤ Protection circuit circuit breaker ⑥ D-Net D-Net Connector 5. Installation guide There is a risk of electric shock. Please be careful when installing the items below. PTS-G5K13M PTS Co., Ltd.
Page 13
Please check that it is properly connected. Power Plug Pin # Phase RF Connection Make sure the power is switched OFF, the Matching Unit and Generator Output is are connected using coaxial cable. PTS-G5K13M PTS Co., Ltd.
Page 14
Connect a Control Signal to the Analog Interface Terminal (D-Sub 25pin) Confirm whether interface 3-5 connected to A/D interface(Pin assignment). 6. A/D Interface (Pin Assignment) Pin No. Name Type Function RF-On,Off Input Contact RF on/off(Max 5V 1mA) INT-L Input Contact Interlock(Max 5V 1mA) PTS-G5K13M PTS Co., Ltd.
Page 15
Analog Interface Connector Pin Functions ① RF On/Off (RF power On/Off Signal) Pin 1,14 Open while RF off, and Close while RF On ② INT-L (Interlock Signal) Pin 2,15 Open if no RF power, Close if there is RF power PTS-G5K13M PTS Co., Ltd.
Pin 7 (Set RF ) ) to a 0 ~ 10V, RF Output Power Set 0 ~ 3,000W to 20 ( A - GND ). ⑦ Pf Moni(FWD Power Monitor) 7. Handy Controller 7-1 Handy Controller Keep in mind that incorrect operation of Handy Controller may a cause problem. PTS-G5K13M PTS Co., Ltd.
Page 17
Liquid crystal display (W 62.0 × H 44.0), Resolution 128 × 64 Buttons A-D Buttons and mini tact switch are used. Key top is a panel sheet film. Software determines operational functions. Communication connector CONT: HR10-7R-6P – Connects with Matching Box CONT connector. PTS-G5K13M PTS Co., Ltd.
Page 18
Function Corresponding to A RF Output Monitor Button Corresponding to B Button Corresponding to C Status Display Button Corresponding to D Button : maintenance Mode (Analog I/O Control). : Internal Control State. RS232 : Communication Control PTS-G5K13M PTS Co., Ltd.
Page 19
※4, pressing [QUIT] ※5 (D Button). ① ※4 ① ※5 ② ② ※6 Confirm Screen OPERATE OPERATE 화면 ↑ OPERATE OPERATE MODE INT A(YES) OR B(NO) QUIT PTS-G5K13M PTS Co., Ltd.
Page 20
↓:Press once to decrease the setting to 50 (It is set in the range of 300msec~5000msec) ① ※8 ① Slow up, down Setting Screen After setup is completed, it can be set by pressing the [QUIT] (D button). PTS-G5K13M PTS Co., Ltd.
Page 21
RF power setting operation of the B button [PF ↑U] ※ 10 and D button [PF ↓ ] ※ 11 . ↑:Pressing once increases the value by 1 . ↓:Pressing once decreases the value by 1. (This change will be effective as you press and hold). PTS-G5K13M PTS Co., Ltd.
Page 22
① ② ※10 ① ※11 ② Alarm Confirmation The error status on alarm confirmation screen of the RF power can be checked. If an error occurs, error checking screen is displayed. Error confirmation screen PTS-G5K13M PTS Co., Ltd.
Amp Err This error occurs due to parts in the amplifier. If the error cannot be reset contact our company. AMP err occurrence frequency may increase if the Load side impedance not 50Ω. PTS-G5K13M PTS Co., Ltd.
Page 24
8-5 Arc Cut 본 Generator는 Arc 발생시 출력 Power를 제어하는 기능이 내장되어 있습니다. Arc발생시 2usec이내에 감지하여 출력 Power를 Off하고 약 10usec후 재출력합니다. 감도는 정격출력의 0~100%까지 지정 가능하며, Ramp up후 활성화되기 때문에 Reflect Power에 의해 오동작을 하지 않습니다. PTS-G5K13M PTS Co., Ltd.
Page 25
Improper handling by the customer ● Use outside of prescribed usage environment ranges ● User modifications ● Natural disasters or accidents causing damage to the unit including but not limited to fire, water leaks, and dropping of the product PTS-G5K13M PTS Co., Ltd.