Contents Safety Precautions System Standard Dimensions RF Generator System Overview Installation A/D Interface RS232C Communication Handy Controller (Remote Operations) Interlock and Alarm Warranty and Maintenace PTS-G5K13M PTS Co., Ltd.
Make sure that all cables and connectors are properly connected. Do not operate this equipment in the potentially explosive environment. Do not operate the generator in area where flammable or explosive gases stored PTS-G5K13M PTS Co., Ltd.
Page 4
All warnings and cautions mentioned in the Manual would advance warning of potential hazards to prevent accidents (see following safety symbols). Thank you for using our RF Generator. PTS and our employees would always be there to manage customer's request. As much as possible, we will do our best to improve customer’s service quality.
It tells you potential activities to reduce serious damage This sign is physical damage due to high voltage. It warns the product weights more than 20kg, and tells to Use Lifting Aids with Proper Lifting Techniques to ask for help. PTS-G5K13M PTS Co., Ltd.
Page 6
This symbol is asked to refer to the Manual for reliable equipment operation. This symbol indicates the position where one has to connect Ground for reliable equipment operation. PTS-G5K13M PTS Co., Ltd.
① Fill out the front and rear of the cooling fan blower of the product smoothly. ② Rack 적재시 전면부(>15cm), 측면부(>15cm), 후면부(>30cm)여 공간과 Rack의 전면부, 후면부에 배기구를 설치해 주십시요. Generator 후면부의 열기가 축적되지 않게 해주십시요. ③ Generator Rack에 6㎥/min이상의 배기팬을 설치하여 주십시요. PTS-G5K13M PTS Co., Ltd.
LED Light turns on when RF-On is on. ALARM Light turns on when there is a warning. TEMP Light turns on when high temperature reading is there. COAX Light up when COAX cover removed. PLUSE Circuit protector Main Switch ③ PTS-G5K13M PTS Co., Ltd.
Page 11
RF control pulse at the output by an external pulse signal (BNC – R) Pulse output connector ④ Analog Interface D - SUB connector, 25P for the A / D Interface (XM2C - 2512) ⑤ RS-232C (D-SUB) D-SUB, 9P connector for RS-232C communication (XM2C- 0912) PTS-G5K13M PTS Co., Ltd.
Always, turn Off power switch and circuit breaker of the power supply before connecting the RF Generator. There is a risk of electric shock, unless you connect the power cable is connected to each phase and ground. Please check that it is properly connected. Power Plug Pin # Phase PTS-G5K13M PTS Co., Ltd.
Control Connection Analog Interface(Analog Voltage Control) Connect a Control Signal to the Analog Interface Terminal (D-Sub 25pin) Confirm whether interface 3-5 connected to A/D interface(Pin assignment). 6. A/D Interface (Pin Assignment) PTS-G5K13M PTS Co., Ltd.
Page 14
RF on Status(Max 30V 100mA) ALARM Output Analog ALARM(Max 30V 100mA) INT/EXT STAT Output Analog INT/EXT Status(Max 30V 100mA) RF Set Input Analog RF Set Voltage(0~+10V=0~1000W) Pf moni Output Analog FWD Monitoring Voltage(0~+10V=0~1000W) Pr moni Output Analog REF Monitoring Voltage(0~10V=0~1000W) PTS-G5K13M PTS Co., Ltd.
Page 15
/ ④ ALARM (Generator internal Alarm Signal) Pin 4,17 Open when normal. Close when internal problem occurs ⑤ INT/EXT Status (INT / EXT Signal state) ⑥ RF Set (RF Power Set voltage) PTS-G5K13M PTS Co., Ltd.
Pin 7 (Set RF ) ) to a 0 ~ 10V, RF Output Power Set 0 ~ 3,000W to 20 ( A - GND ). ⑦ Pf Moni(FWD Power Monitor) 7. RS232C Communication Communication Specification Baudrate 57,600bps Data width 8bits Parity Even Flow control none PTS-G5K13M PTS Co., Ltd.
Page 17
7-2 Communication Protocol <————————— Length —————————> DATA <———————————— CRC ————————————> Name Size Function Start Marker (0x05) Length Command DATAn DATA field CRC (XOR calc.) End Marker (0x0A) PTS-G5K13M PTS Co., Ltd.
Page 18
← abnormal response *1: if request command is "set" then 2'b10XXXXXX(X=base command) fixed if request command is "get" then 2'b11XXXXXX(X=base command) variable *2: ER(Error Code) null 0xF0:Communicaton Error 0xF1:CRC Error 0xF2:Data Error 0xF3:E2PROM Error PTS-G5K13M PTS Co., Ltd.
Page 19
[12:0] slow-up time [12:0] slow-up time 300~5,000(0x012C~0x1388) 300~5,000(0x012C~0x1388) [15:13] null [15:13] null not assignment. write data is '0'. not assignment. read data is '0'. [NOTE] [NOTE] slow-up time unit is "ms". slow-up time unit is "ms". PTS-G5K13M PTS Co., Ltd.
Page 20
0:normal, 1:abnormal [10] coax 0:normal, 1:abnormal [11] pr-trip 0:normal, 1:abnormal [12] flow 0:normal, 1:abnormal [13] 0:normal, 1:abnormal [14] reserved [15] HD CON 0:disable, 1:enable [22:16] arc-cut count 0~100(0x0000~0x0064) [31:23] null not assignment. read data is '0'. [NOTE] PTS-G5K13M PTS Co., Ltd.
Liquid crystal display (W 62.0 × H 44.0), Resolution 128 × 64 Buttons A-D Buttons and mini tact switch are used. Key top is a panel sheet film. Software determines operational functions. Communication connector CONT: HR10-7R-6P – Connects with Matching Box CONT connector. PTS-G5K13M PTS Co., Ltd.
Page 22
Function Corresponding to A RF Output Monitor Button Corresponding to B Button Corresponding to C Status Display Button Corresponding to D Button : maintenance Mode (Analog I/O Control). : Internal Control State. RS232 : Communication Control PTS-G5K13M PTS Co., Ltd.
Page 23
※4, pressing [QUIT] ※5 (D Button). ① ※4 ① ※5 ② ② ※6 Confirm Screen OPERATE OPERATE 화면 ↑ OPERATE OPERATE MODE INT A(YES) OR B(NO) QUIT PTS-G5K13M PTS Co., Ltd.
Page 24
↓:Press once to decrease the setting to 50 (It is set in the range of 300msec~5000msec) ① ※8 ① Slow up, down Setting Screen After setup is completed, it can be set by pressing the [QUIT] (D button). PTS-G5K13M PTS Co., Ltd.
Page 25
RF power setting operation of the B button [PF ↑U] ※ 10 and D button [PF ↓ ] ※ 11 . ↑:Pressing once increases the value by 1 . ↓:Pressing once decreases the value by 1. (This change will be effective as you press and hold). PTS-G5K13M PTS Co., Ltd.
Page 26
① ② ※10 ① ※11 ② Alarm Confirmation The error status on alarm confirmation screen of the RF power can be checked. If an error occurs, error checking screen is displayed. Error confirmation screen PTS-G5K13M PTS Co., Ltd.
Amp Err This error occurs due to parts in the amplifier. If the error cannot be reset contact our company. AMP err occurrence frequency may increase if the Load side impedance not 50Ω. PTS-G5K13M PTS Co., Ltd.
Page 28
9-5 Arc Cut 본 Generator는 Arc 발생시 출력 Power를 제어하는 기능이 내장되어 있습니다. Arc발생시 2usec이내에 감지하여 출력 Power를 Off하고 약 10usec후 재출력합니다. 감도는 정격출력의 0~100%까지 지정 가능하며, Ramp up후 활성화되기 때문에 Reflect Power에 의해 오동작을 하지 않습니다. PTS-G5K13M PTS Co., Ltd.
Page 29
Improper handling by the customer ● Use outside of prescribed usage environment ranges ● User modifications ● Natural disasters or accidents causing damage to the unit including but not limited to fire, water leaks, and dropping of the product PTS-G5K13M PTS Co., Ltd.