For your safety operation
The Lynx-CustomFit® Splice-On Connector is designed
and manufactured to assure personal safety. Improper
operation can result in bodily injury and serious damage
to this product. Please read and observe all warnings
instructions given in this operation manual.
Wear safety glasses
!
handling optical fiber.
Never look into
!
optical cable connected to an optical output
device that is operating. Laser radiation is
invisible, and direct exposure can severely injure
the human eye.
!
Alcohol is
flammable, causes irritation and is
harmful if swallowed or inhaled. Keep alcohol
away from heat, sparks, skin, and avoid contact
!
with eyes.
In the case of the work at the high place, please
be careful not to drop an assembling tool.
Disposable
Holder (*1)
Front
Housin
g
(*1) 1 pc / 100 connectors
Recommended Program
Splicer
Fiber
T-25eS
SMF
MMF
T-39FH
SMF
MMF
T-Q101-CA
SMF
(T-71C)
MMF
SMF : G.652, G.657
MMF : MM50(OM2), MM50(OM3), MM50(OM4), MM62.5(OM1)
North Carolina (USA)
Sumitomo Electric Lightwave Corp.
78 Alexander Drive, P.O. Box 13445, RTP, NC
27709
TEL +1-919-541-8100
http://www.sumitomoelectric.com/
Copyright © 2011 Sumitomo Electric Industries, LTD.
Lynx
-
CustomFit
Lynx
-
CustomFit
-
LC
for
Optical
-
LC
for
Optical
to protect your eyes when
the end of a microscope or
Composition
Furcation
Rear
Boot
Stopper
Ferrule
Subassemb
ly
Splicing Program Heater
Program
SM1: SMF1C
Lynx
or FPS (60mm)
MM1: MMF1C
LYNX-SM
Lynx
or FPS (60mm)
LYNX-MM
Standard SMF
Lynx
or 60mm 0.9
MMF 50&62.5
London (UK)
Sumitomo Electric Europe Ltd.
220 Centennial Avenue, Elstree, Herts. WD6
3SL, UK
TEL +44 (0)20-8953-8118
http://www.sumielectric.com/
®
Splice
-
On
Connector
®
Splice
-
On
Connector
Cord
(2.4/3mm)
Cord
(2.4/3mm)
Installation
Installation
Manual
Manual
1. Improper assembly will result in a loss of
performance.
operation manual and the operation manual of the
fusion splicer.
2.
Never touch the fiber of the
inspected in the factory.
3. The product is sensitive to dirt or dust. Do not take
out any parts from the package
used.
4. The characteristic will be influenced by the fiber
cleaved surface condition. Please use a cleaver
which has a good cleaving characteristic.
5. Do not remove the dust cap
has been completely assembled
cause an high insertion loss due to them.
Below tools are required.
Tube
Fiber Holder
LYNX2-UML-S
Protection
Sleeve
Below equipments or tools are examples.
Fusion Splicer
and Spring
T-Q101-CA,
etc.
Holder Type
Please perform Arc test prior to the splicing
operation.
(See the operation manual of the splicer.)
*Fiber for testing is not included in the kit.
Please check fiber type inside the field fiber.
Ver. 2
Ver. 2
with
Duplex
LC
Clip
with
Duplex
LC
Clip
Precautions
Please read instructions
stub. It has been
until it is to be
until the connector
in order not to
Assembling Tools
Cord Tool
LYNX2-
CORDTOOL
Fiber Cleaver
Jacket remover
FC-6S-C, etc.
JR-M03, etc.
Cleave length:
10mm
Yokohama (Japan)
Sumitomo Electric Industries, Ltd.
(Lightwave Network Products Division)
1, Taya-cho, Sakae-ku, Yokohama 244-8588,
Japan
TEL +81-45- 853-7223, http://global-
sei.com/fttx/
-
-
given in this
Kevlar Cutter
Need help?
Do you have a question about the Lynx-CustomFit LYNX2-LC and is the answer not in the manual?
Questions and answers