Provision Of Ventilation; Operation - Thetford SPINFLO S-FI24000 Installation - Use - Maintenance

Build in gas fire models
Table of Contents

Advertisement

INTRODUCTION
This appliance must be installed in accordance with the local, national and European
regulations in force. Particular attention shall be given to the requirements regarding
ventilation. Read the instructions before installing or using the appliance. The
appliance MUST be installed by an approved competent person.
Failure to install the appliance correctly could invalidate any warranty or liability claims and
lead to prosecution. Please refer to the methods of installation within this handbook.
Our policy is one of continuous development and improvement. Specifications and
illustrations may change subsequent to publication.

PROVISION OF VENTILATION

The use of a gas appliance results in a production of heat and moisture in a room in which it
is installed. Ensure the room is well ventilated, keep natural ventilation holes open or install a
mechanical ventilation device, (mechanical extractor fan).
Prolonged intensive use of the appliance may call for additional ventilation, for example
opening a window, or more effective ventilation, for example increasing the level of
mechanical ventilation where present.
The room containing the fire should have an air supply in accordance with local and
national/European standards.
POSITION
This appliance must be positioned free from draughts, which may affect the combustion, and
in a manner that will prevent the accumulation of unburnt gas. When in use ensure that air
vents are not inadvertently blocked or shut off.

OPERATION

The burner on this appliance has fixed aeration and no adjustment is required. Depending on
the gas being used, the burners should flame as follows: -
Propane -
The flames should burn quietly with a blue/green colour with no sign of yellow
tips.
Butane -
Normally on initial lighting, a small amount of yellow tipping will occur and then
slightly increases as the burner heats up.
Natural gas - The flames should burn with a blue/green colour with no sign of yellow tips.
THE APPLIANCE IS FITTED WITH AN OXYGEN DEPLETION SENSOR AS
STANDARD. THE SENSOR WILL EXTINGUISH THE FLAME IF
EVACUATION OF THE COMBUSTION PRODUCTS IS INTERRUPTED.
IF THE OXYGEN DEPLETION SENSOR OPERATES REPEATEDLY TURN
OFF THE GAS AND CONTACT YOUR DEALER.
LPG (GAS) APPLIANCES MUST NOT BE INSTALLED BELOW
GROUND LEVEL. E.G. IN A BASEMENT.