Thetford SPINFLO S-FI24000 Installation - Use - Maintenance

Build in gas fire models

Advertisement

Quick Links

BUILD IN APPLIANCES
FOR USE WITH LIQUIFIED PETROLEUM GAS (LPG) OR NATURAL GAS
CAUTION – ALL OUTER SURFACES WILL GET HOT WHEN IN USE
GAS FIRE MODELS
S~FI24000 (LPG)
S~FI24000NG (Natural Gas)
INSTALLATION, USE & MAINTENANCE
SPINFLO LIMITED, Unit 19, Oakham Drive, Parkwood Industrial Estate
Rutland Road, Sheffield S3 9QX, ENGLAND.
TEL: + 44 (0) 114 273 8157
FAX: + 44 (0) 114 275 3094

Advertisement

Table of Contents
loading

Summary of Contents for Thetford SPINFLO S-FI24000

  • Page 1 BUILD IN APPLIANCES FOR USE WITH LIQUIFIED PETROLEUM GAS (LPG) OR NATURAL GAS CAUTION – ALL OUTER SURFACES WILL GET HOT WHEN IN USE GAS FIRE MODELS S~FI24000 (LPG) S~FI24000NG (Natural Gas) INSTALLATION, USE & MAINTENANCE SPINFLO LIMITED, Unit 19, Oakham Drive, Parkwood Industrial Estate Rutland Road, Sheffield S3 9QX, ENGLAND.
  • Page 2: Natural Gas

    MODEL S~FI24000 S~FI24000NG NATURAL GAS Gas Type (G30 & G31) (G20) Size, mm H x W x D H x W x D Fire Front 602 x 498 x 89 602 x 498 x 89 Rear Box 542 x 383 x 158 542 x 383 x 158 Total Input 3.8kW...
  • Page 5: Provision Of Ventilation

    INTRODUCTION This appliance must be installed in accordance with the local, national and European regulations in force. Particular attention shall be given to the requirements regarding ventilation. Read the instructions before installing or using the appliance. The appliance MUST be installed by an approved competent person. Failure to install the appliance correctly could invalidate any warranty or liability claims and lead to prosecution.
  • Page 6: Maintenance

    OPERATION Ensure the gas cylinder is turned on. In the event of a gas smell, turn off at the cylinder and contact supplier. IGNITION (1) Press in the control knob. (2) Keeping the control knob pressed in rotate the knob anti- clockwise, until the spark igniter clicks twice.
  • Page 7: Installation

    The flue cavity MUST be ventilated, we recommend a flue terminal with integrated vent (Please contact Spinflo by Thetford for details) or by a vent in the wall. The gas escape vent should be positioned as detailed on the included installation drawings and MUST be baffled to prevent direct draught to the fire.
  • Page 8: Gas Connection

    INSTALLATION POSITION All models must be installed and positioned on a hearth with a minimum distance of 60mm from the outside of the surround trim to the outside of the hearth. The hearth should also extend a minimum of 60mm from the front of the grate – see Fig. 2. If the fire is to be installed with a shelf/curtain above, the shelf/curtain must be a minimum of 100mm above the surround trim and not exceed 160mm in depth –...
  • Page 9: Operational Tests

    INSTALLATION OPERATIONAL TESTS Ensure the gas cylinder is turned on. Check the ignition functions correctly and the pilot remains lit Turn to high rate, check function correct. Turn off, check flame extinguished and knob position correct Test For Spillage THIS TEST MUST BE CARRIED OUT BEFORE THE INSTALLATION IS PASSED OVER TO THE CUSTOMER.
  • Page 10 SERVICE ALL SERVICING MUST BE CARRIED OUT BY AN APPROVED COMPETENT PERSON AFTER EACH SERVICE THE APPLIANCE MUST BE CHECKED FOR GAS SOUNDNESS AT LEAST ONCE EVERY 12 MONTHS THE FIRE, FLUE & TERMINAL SHOULD BE CHECKED FOR CORRECT OPERATION. 1.