U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Control Unit ECO-NET 128 Use and Maintenance Instructions Version: 1.02 Issue: March 2021 TURBO s.r.l. InMn 26 UCESTD Dust Filter Components it Rev.1.02...
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Description ____________________________________________________________________ 3 General features _______________________________________________________________ 4 Dimensions and measurements _________________________________________________ 5 Mechanical fixing ______________________________________________________________ 5 Warning Symbols Used in the Manual __________________________________________ 6...
The Eco-net 128 has a graphic LCD with menu in 5 languages, through which the user can control the entire cleaning process and make settings by accessing the various menus via a series of buttons positioned on the front panel of the control unit.
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit General features 100÷240Vac 50-60 Hz Power supply voltage Optional: 24Vac/Vdc ± 10 % 25W at max load Electric consumption (with Ton max=10sec) (35W per 24Vac/Vdc IN) (100÷240Vac IN)
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Dimensions and measurements Mechanical fixing TURBO s.r.l. InMn 26 UCESTD Dust Filter Components it Rev.1.02 Via Po 33/35 20811 Cesano Maderno (MB) Italy Tel ++39 0362 574024 Fax ++39 0362 574092...
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Warning Symbols Used in the Manual The indications regarding safety are highlighted using the following symbols: Attention - Danger Warning - Generic Risk –...
Page 7
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit ▪ The cable glands are selected in relation to the diameter of the cable use. ▪ Sealing of the cable gland is guaranteed by the compression of the rubber gasket, which tightens on the external diameter of the cable.
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit General connection diagram Connections key Pos. Description Notes P1 (1-2-3) Main power supply connector “Cleaning Fan Off” input contact (Post pul.)
H05VV-F 0.75mm – 19AWG. The cable connected to the P11 connector of the Eco-Net 128 control unit, must be introduced into the “IN” port of the first valve actuator present on the chain, using a PG7 type connector, complete with seals supplied, to guarantee the IP sealing of the circuit.
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Connection layout to the ERCP pilot enclosure boxes Connect the 3-wire cable coming from the IN connector of the first pilot enclosure box for pneumatic...
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Display and keyboard There are 5 round keys on the front panel, used to access the equipment functions. When turned on, the display shows the name of the control unit and the firmware/hardware version on the first page.
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Main Menu The main menu can be accessed by pressing the "MENU" button on the main screen. Using the “” and “” buttons, it is possible to select the category desired and, by confirming with “OK”, the individual configuration...
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Advanced Set Up Unit Factory Description Range settings measurement dP Fan On/Off The threshold value for fan on or off...
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Alarms Factory Unit settings Description Range measurement dP Dirty filter KPa/1000 3000 Set the pressure ΔP value to generate the clogged filter alarm 10000 Enabling Min.
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Counters Unit Factory settings Description Range measurement Hours Power The control unit switch-on hour meter is displayed. 9999999 Pulse count...
Page 16
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Continues..Unit Factory settings Description Parameter Range measurement Method of activation of Relay 2 Pulse The activation mode of Relay 2 during...
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Operating mode The operating modes of the Eco-Net 128 control unit are shown below. They can be activated by setting the relative parameter of the "Main Set Up" menu. Manual mode In this mode, the Eco-Net 128 control unit operates as a programmable cyclic sequencer.
Special manual mode In this mode, the Eco-Net 128 control unit activates the valves with the times indicated in manual mode (Ts, Tc), for the number of cycles programmed in the "Cycles Spec. Man." (nS) parameter, introducing a pause between one cycle and another with a value corresponding to the "Pause.
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Functionality Cleaning with fan off (Post -Cleaning) This function allows a cleaning cycle to be run with the fan off. Its activation is automatic in "Auto matic"...
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit The remote enabling input is found on terminals 6-7 (terminal P16) of the control unit. A voltage-free contact (switch, relay contact,...) must be connected to this input which, when closed, ena bles the control unit to function.
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Setting the pressure thresholds dP The control unit software has a limitation function of the pressure threshold settings regarding the “dP Start”, “dP Stop”...
Page 22
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit The following table gives the default values (KPa column) programmed in the control unit on leaving the factory and, by comparison, the same value with respect to the scales available:...
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Maintenance Apart from the fuse, the Econet control unit does not have replaceable parts. All other repairs must be carried out by the manufacturer.
U s e r I n s t r u c t i o n s Eco-Net 128 Control Unit Troubleshooting FAQ Fault Possible cause Solution Check the protection fuse on the circuit board. The display does not turn on.