ebm-papst W2E200-HK38-01 Operating Instructions Manual

ebm-papst W2E200-HK38-01 Operating Instructions Manual

Hide thumbs Also See for W2E200-HK38-01:

Advertisement

Quick Links

W2E200-HK38-01
CONTENTS
Item no. 10760-5-9970 · ENU · Change 203512 · Approved 2019-04-29 · Page 1 / 11
Operating instructions
·
·
·

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
DANGER
2
Indicates an imminently hazardous situation which will result in
2
death or serious injury if the specified actions are not taken.
2
Compliance with the instructions is imperative.
2
WARNING
2
Indicates a potentially hazardous situation which can result in
2
death or serious injury if the specified actions are not taken.
3
Exercise extreme caution while working.
CAUTION
4
Indicates a potentially hazardous situation which can result in
4
minor or moderate injury or damage to property if the specified
5
actions are not taken.
5
5
NOTE
5
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
6
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
7
maintained and otherwise used by suitably qualified, trained and
8
authorized technical staff.
9
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
9

1.3 Basic safety rules

9
The safety hazards associated with the device must be assessed again
10
following installation in the final product.
10
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.
·
·
·

Advertisement

Table of Contents
loading

Summary of Contents for ebm-papst W2E200-HK38-01

  • Page 1: Table Of Contents

    Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions W2E200-HK38-01 CAUTION → Do not wear any loose-fitting or dangling clothing or jewelry Electric charge on capacitor after device is switched off while working on rotating parts. Electric shock, risk of injury → Protect long hair with a cap.
  • Page 3: Intended Use

    Operating instructions W2E200-HK38-01 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions W2E200-HK38-01 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Direction of air flow "V" For self-tapping M5 screws Item no. 10760-5-9970 · ENU · Change 203512 · Approved 2019-04-29 · Page 4 / 11 · ·...
  • Page 5: Nominal Data

    With regard to cyclic speed loads, note that the rotating parts of Valid for approval/ the device are designed for a maximum of one million load standard cycles. If you have special questions, consult ebm-papst for Speed (rpm) / min 2550 2800 support.
  • Page 6: Connection And Startup

    ; If the motor run capacitor was not installed by ebm-papst, check whether the information on the motor run capacitor matches the → Ensure stress-free attachment of the fan to the information on the nameplate.
  • Page 7: Connection Via Terminal Strip

    Operating instructions W2E200-HK38-01 Heating-up of the motor when using a variable frequency drive must be checked by the customer following installation in the end device. 4.3 Connection via terminal strip 4.3.1 Connecting wires to terminals WARNING Live terminals and connections even with device...
  • Page 8: Connection Diagram

    Operating instructions W2E200-HK38-01 4.4 Connection diagram green/yellow black blue Item no. 10760-5-9970 · ENU · Change 203512 · Approved 2019-04-29 · Page 8 / 11 · · · · · ·...
  • Page 9: Checking Connections

    Operating instructions W2E200-HK38-01 4.5 Checking connections 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES ; Ensure isolation from supply (all phases). ; Make sure a restart is impossible Do not perform any repairs on your device. Send the device to ebm- ;...
  • Page 10: Cleaning

    Deficient cooling Improve cooling Contact Visual inspection At least every Repair or protection 6 months replacement of In the event of further malfunctions, contact ebm-papst. cover for device intactness or damage 5.1 Cleaning Device for Visual inspection At least every...
  • Page 11 ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 10760-5-9970 · ENU · Change 203512 · Approved 2019-04-29 · Page 11 / 11 · ·...

Table of Contents