Advertisement

Medical Infrared Thermometer
PC809 / PC809EV / PC809V
User' s Manual
Version 2.0
2019.09.01

Advertisement

Table of Contents
loading

Summary of Contents for PACOM PC809

  • Page 1 Medical Infrared Thermometer PC809 / PC809EV / PC809V User’ s Manual Version 2.0 2019.09.01...
  • Page 3: Table Of Contents

    Contents 1.Introduction ..................1 2.Packing list ..................1 3.Product description................1 3.1 Overview...................1 3.2 Intended use................2 3.3 Principle..................2 3.4 Features..................3 3.5 Components................3 3.6 Product structure..............4 3.7 LED display description.............. 4.Warnings and precautions.............5 5.Directions for use................7 5.1 Take your forehead temperature..........7 5.2 Take your ear temperature............8 5.3 Recall saved readings..............10 5.4 ℃...
  • Page 4: Introduction

    Models covered for this manual and their differences are as follows: Model Difference At the end of temperature measurement, the PC809 buzzer gives a ‘beep’ cue. At the end of temperature measurement, the PC809EV speaker broadcasts the temperature in English.
  • Page 5: Packing List

    2. Packing list Medical infrared thermometer 1 pc Storage bag 1 pc User’ s manual 1 pc AAA dry cell battery (optional) 2 pcs 3. Product description 3.1 Overview The Medical Infrared Thermometer measures body temperature based on detecting infrared energy emitted from the eardrum or forehead.
  • Page 6: Intended Use

    3.2 Intended use The multifunctional infrared thermometer is intended for measuring human body temperature. It has two measurement modes: the forehead mode for people of all ages and the ear mode for people above the age of three months. 3.3 Principle The infrared temperature sensor collects infrared energy emitted by the eardrum in the ear canal or the skin of the forehead.
  • Page 7: Features

    3.4 Features Quick measurement in just 1 second Accurate and reliable One button design, making it easy to operate Both forehead and ear measurement modes 32 memory slots, making it easy to save and recall temperatures Switch between Celsius (℃) and Fahrenheit (℉) Turn on/off...
  • Page 8: Led Display Description

    Fig. 5 (remove probe cover) ① Probe cover (remove it when measuring ear temperature) ② LED display screen ③ Power/Measure/Set button ④ Top Cover ⑤ Infrared sensor ⑥ Label ⑦ Buzzer/Speaker outlet ⑧ Battery cover ⑨ Probe 3.7 LED display description Fig.
  • Page 9: Warnings And Precautions

    ① Green status light ② Orange status light ③ Red status light ④ Low battery indicator ⑤ Ear temperature mode ⑥ Forehead temperature mode ⑦ Memory mode ⑧ Celsius ⑨ Fahrenheit ⑩ Temperature value 4.Warnings and precautions 1) Keep out of reach of children under 12 years of age. 2) Never immerse the thermometer in water or other liquid (it is not waterproof ).
  • Page 10 9) Temperature elevation may signal a serious illness, especially in adults who are elderly, frail or have a weakened immune system, or neonates and infants. Please seek professional advice immediately when there is a temperature elevation in a person who meets any of the following criteria: Over 60 years of age (fever may be dulled or even absent in elderly patients)
  • Page 11: Directions For Use

    5. Directions for use Please load the batteries before using the thermometer. Take the batteries out if you will not use the thermometer for a long time, such as over one month. Additionally, referring to Part 3 in Fig. 3, this thermometer has a one-button design, so when we describe the ‘Power button’...
  • Page 12: Take Your Ear Temperature

    In order to improve accuracy, please make sure that your forehead is free from hair, sweat or dirt. Make sure the probe sensor is clean before using the thermome- ter. Ensure that both the user and thermometer remain in the same room with a stable airflow and a room temperature between 10.0‒40.0℃...
  • Page 13: Recall Saved Readings

    Be careful when taking the ear temperature of a child, as their ear canals are small. When taking the ear temperature of a child aged over 1 year or an adult, gently pull the ear up and back to make the ear canal straight, allowing the probe to receive infrared rays from the eardrum.
  • Page 14: Turn On/Off Buzzer/Speaker/Vibration

    5.5 Turn on or off the buzzer/speaker/vibration The PC809, PC809EV, PC809V models are different in how they interact with users when measurement is complete: the PC809 uses a buzzer to ‘beep’ , the PC809EV communicates the temperature in English through a speaker and the PC809V uses a motor to vibrate.
  • Page 15: Set Threshold For High Fever

    5.7 Set threshold for high fever This thermometer has 38.0℃/100.4℉ preset as an alarm tempera- ture for high fever. However, 38.0℃/100.4℉ is only a classic reference value. At this temperature, different people feel different, with some feeling bad and others not feeling too bad. If you do not agree with this high fever threshold, after consulting your doctor, you can manually change it to suit your own situation.
  • Page 16: Temperature-Taking Tips

    6. Temperature-taking tips 1) It is important to know the normal temperature of each individual when they are well. This is the only way to accurately diagnose a fever. Record readings twice a day, once in the early morning and once in the late afternoon. Take the average of these two temperatures to obtain the normal oral equivalent tempera- ture.
  • Page 17: Cleaning And Disinfection

    7) In the following situations, it is recommended to measure 3‒5 times in the same location and take the highest temperature as the reading: a) Newborn infants in the first 100 days; b) Children under 3 years of age with compromised immune systems;...
  • Page 18: Disinfection

    Keep the infrared sensor lens away from water during the cleaning process, or else it may be damaged. The infrared sensor lens may be scratched if it is cleaned with a piece of tissue paper, resulting in inaccurate readings. Do not allow the infrared sensor lens to make contact with hard objects.
  • Page 19: Troubleshooting

    8. Troubleshooting Sy m pto m Po s s i ble Cau s e Solut i on The battery level is too low Replace the batteries. Fa i le d to The polarities of the Ensure that the batteries are batteries are reversed inserted correctly.
  • Page 20: Specifications

    9. Specifications Medical Infrared Thermometer Product name Product model PC809/PC809EV/PC809V Applicable ASTM E 1965 / EN12470-5 / GB/T 19146 regulations and laws Power supply DC 3.0V (2 × AAA batteries) Battery life More than 2,000 measurements Appears on the screen when the voltage is Low battery indicator below 2.6V±0.1V...
  • Page 21: Symbol Descriptions

    10. Symbol descriptions De sc ri pt i on Sy mbo l Type BF applied part. Information about the manufacturer, such as name and address. Please read the instructions carefully. Waste electrical materials should be sent to a dedicated collection point for recycling. Serial number Batch number IMPORTANT...
  • Page 22: After-Sales Service

    12. After-sales service This device is under warranty for one year from the date of acquisition. Applications for repairs should be presented during the warranty period. Damage caused by improper use does not fall under the scope of the warranty. Batteries and packaging are also not covered by the warranty.
  • Page 23 Guidance and manufacturer’ s declaration - electromagnetic emissions - for all EQUIPMENT and SYSTEMS Guidance and manufacturer’ s declaration - electromagnetic emissions The Medical Infrared Thermometer is intended for use in the electromagnetic environment specified below. The customer or user of the device should ensure that it is only used in such an environment.
  • Page 24 Guidance and manufacturer’ s declaration - electromagnetic immunity - for EQUIPMENT and SYSTEMS that are not LIFE-SUP- PORTING Guidance and manufacturer’ s declaration - electromagnetic immunity The Medical Infrared Thermometer is intended for use in the electromagnetic environment specified below. The customer or user of the device should ensure that it is only used in such an environment.
  • Page 25 Recommended separation distances between portable and mobile RF communications equipment and the EQUIPMENT or SYSTEM - for EQUIPMENT and SYSTEMS that are not LIFE-SUP- PORTING Recommended separation distances between portable and mobile RF communications equipment and the Medical Infrared Thermometer. The Infrared Thermometer is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
  • Page 26: Manufacturer Information

    15. Manufacturer information Shenzhen Pacom Medical Instruments Co., Ltd. Add: Area B, 8/F, Building B, No. 5 Industrial Five Road, Jiangbian Community, Songgang Subdistrict, Bao’ an District, Shenzhen, Guangdong 518105, CHINA Tel: +86-755-32920339 Email: sales888@pacomsz.cn - 23 -...

This manual is also suitable for:

Pc809evPc809v

Table of Contents