8.
Click Next , bring up Fig. 22.
- Click Finish to exit the Step window.
- Serial number can be filled up at this moment (for example, TY
000658).
NOTE: You must modify the Serial NO. In step 9, otherwise the Serial NO.
In OSD Couldn't be modified correctly.
Step 5: Write DDC data
1. Configuration should be as Fig. 23. And press OK.
2. Access Factory Mode
1). Turn off monitor.
2).
[Push "AUTO" & "OK" buttons at the same time and hold them]
+[Press "power" button untill comes out "Windows screen" ]
=> then release all buttons
3).Press "OK" button, wait until the OSD menu with Characters
"HUDSON 170B6 V023 2004/12/06" (below OSD menu) come
on the Screen of the monitor(See Fig.24).
Factory Mode
Indicator
3) Push Menu to exit OSD menu.
"
"
DDC Instructions
4). Click
the screen will be black for 2-3 seconds,then the screen recovers,
and "ATTENTION NO VIDEO INPUT"will come on the screen of the
monitor,wait for 20-30 seconds ,DDC data will be finished Writing.
Step 6: Save DDC data
Sometimes, you may need to save DDC data as a text file
for using in other IC chip. To save DDC data, follow the
steps below:
1. Click
bar and give a file name as shown in Fig. 25.
The file type is EDID46 file (*.ddc) which can be open in
WordPad. By using WordPad, the texts of DDC data & table
(128 bytes, hex code) can be modified. If DDC TEXTS &
HEX Table ar completely correct, it can be saved as .ddc flie
to re-load it into DDC IC for DDC Data application.
Fig. 22
2.
Click Save.
Step 7: Exit DDC program
Fig. 23
Pull down the File menu and select Exit as shown in Fig. 26.
Step 8: Turn off the monitor, exit the factory mode.
Fig. 24
170B6 LCD
(Write EDID) icon from the tool bar to write DDC data. then
(Save) icon (or click "file"-> "save as") from the tool
Fig. 25
Fig. 26