PF9700 Automated Hinge Gate
Installation, Operation &
Maintenance Manual
Parking and access control equipment manufactured in the UK
Rev:8.2 -19
Manual Barriers
Auto Sliding barriers
Auto Bi-Fold barriers
Auto Rising Kerbs
Auto Rising Bollards
Turnstiles

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PF9700 and is the answer not in the manual?

Questions and answers

Summary of Contents for Parking Facilities PF9700

  • Page 1 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Rev:8.2 -19 Installation, Operation & Maintenance Manual Manual Barriers Auto Sliding barriers Auto Bi-Fold barriers Auto Rising Kerbs Auto Rising Bollards Turnstiles...
  • Page 2: Wiring Diagram

    Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate INDEX Page No: INTRODUCTION & WARNINGS DELIVERY, TRANSPORT & MOVEMENT COMPONENT OVERVIEW 05 - 06 MANUAL RELEASE GUIDE FIRST OPERATION MANOEUVER PANEL USAGE GUIDE TROUBLESHOOTING GUIDE 10 - 11...
  • Page 3: Introduction And Warnings

    Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Introduction and Warnings This equipment is part of a large range of traffic flow products. They are designed to be easy to install, as all settings and internal wiring have been completed in our factory.
  • Page 4 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Delivery, Transport & Movement This article describes how your equipment will be delivered to you, specifications on the transportation used and advice including health & safety on movement of the equipment.
  • Page 5: Component Identification

    Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Component Identification TST FUZ-PF M12 Bolt Control Panel 4 No. (Centre Stop) *Manual Winding Handle Loop Detector Internal Master/Slave module (Optional) TSTRUFZ-COM PRES PULSE FILT SENS FREQ...
  • Page 6 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Component Identification 60 5 45 mins Duct Hole earth product 5. Assuming that the gate has now been closeed onto the threaded bar and has been levelled accordingly the duct can be pushed through the hole in the gate tower.
  • Page 7 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Manual Release Guide Please use the following instructions to operate the Gate manually, the following is assuming you have powered down the unit and opened the cabinet door:...
  • Page 8 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate First Operation Manouvres 1.Before attempting the steps outlined below please obey common sense and make sure that you have closed the passage the Gate will inhibit provided a diversion and informed site inc pedestrians.
  • Page 9 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Panel Usage Guide 60 5 10 mins UP ARROW STOP STOP BUTTON STOP DOWN ARROW figure.1 figure.2 LED Letters or numbers .0.99 P.999 LED Dot figure.4 Normal State = Static Changed State = Flashing figure.3...
  • Page 10: Troubleshooting Guide

    Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Troubleshooting Guide Message Cause of message Short description: • current motor run time has exceeded set maximum run time (P.410 (Opening), P.415 (Closing), P.419 (Deadman move)), door Run time exceeded (during opening, F.020...
  • Page 11 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Troubleshooting Guide Message Short description: Cause of message I.080 Service counter will run off I.100 Speed in open position to high I.150 Speed in close position to high I.160...
  • Page 12 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Wiring Diagram (Illustration) Basic Information: All inputs are on the right hand side of the board as you look at it. ANY of these are easily configured, for example any contact can be changed by a parameter from Normally Open to Normally Closed etc.
  • Page 13 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Every input/output is highly configurable, and can be changed from its default/state use. The below is a guide to what they can be changed to and the effect of this change. The logic behind this is as follows: On the wiring diagram each terminal has an input number this is noted as “IN6"...
  • Page 14 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Inputs Parameter Unit Range Function Description/Value of Parameter P.7x0 0 ..27 Switching With this parameter the functionality for parameter x is set. Condition of output relay Notes Area...
  • Page 15 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate OPERATING INSTRUCTIONS 1 CHANNEL LOOP DETECTOR LAYOUT Stock Code: TST-SUVEK1 1. Turn OFF power to the control panel. 2. Plug the loop detector module into the pins provided on the motherboard of the control panel.
  • Page 16 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Troubleshooting Guide ELECTRICAL ERRORS CAUSE CORRECTION Door switch circuit not making Press door switch in and check Panel screen Blank screen on Panel but power to other...
  • Page 17 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Troubleshooting Guide (Mechanical) MECHANICAL ERRORS CAUSE CORRECTION Gate arm keeps going up and down Limit switch fault check and reset limit switches Gate creaking when moving Check turn buckle...
  • Page 18 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Troubleshooting Guide (Mechanical) Please note these are things that you should look out for with the equipment that has been installed on your/your customers site. This is in no way a health and safety guide just a few key areas for you to be aware of and possibly make future changes to.
  • Page 19: Installation/Commissioning Check List

    Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Installation/Commissioning Check List System Operation - The user FULLY understands How to operate the system with all control devices How to isolate the power to the automation system...
  • Page 20: Service Log

    Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Service Log This Manual must be completed in accordance with the guidelines below, at any point service/repair work is carried out on the product. This is to achieve two things;...
  • Page 21: Commissioning Certificate

    Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Commissioning Certificate We certify that the system covered by this certificate has been commissioned satisfactorily. Contract Reference Completion Engineers Installing Contract Title Installation Commenced Commissioning Works Description...
  • Page 22 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Electronics Certificate...
  • Page 23: Certificate Of Conformity

    Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Certificate of Conformity The machinery which this declaration refers to, is in accordance with the conditions of the following directives; Machinery Directive 2006/42/EC. Low Voltage Directive 2006/42/EC.
  • Page 24 Parking and access control equipment manufactured in the UK PF9700 Automated Hinge Gate Electric Motor: Geared Motor Spec: 400v 50hz 3 phase Braked Motor Type: Worm & Wheel 4 pole Overall speed: 200 rpm IP54 Max rated torque: 320nm B14 C face mounted...

Table of Contents