SALTDIP™ Pro
SALTDIP™ Pro is an electronic testing device for accurate measurement of both salinity and
temperature of swimming pool and spa water.
Contents
1. Carrying case with Padded Foam Protection
2. Handheld Meter with stainless steel battery
cover and rugged rubber casing
3. Salt Conductivity / Temperature Probe w/
Stainless Steel Probe Guard
4. Removable 3 Ft Extension Cable
5. 4000ppm NaCL Calibration Solution
6. Quick Start Guide
Not Supplied:
· 2 AAA Batteries
· Flat head screwdriver or a coin to open
battery compartment
SALTDIP™ PRO Display Indicators
Salt measurement display (NaCL ppm)
Temperature display C/F
Measurement in progress
Battery level indicator
Measurement completed
Last saved reading
Error warning
Measurement
1. Prior to testing, swish dry probe in water for 5 seconds to moisten sensor.
2. Gently drop probe into sample water (pool, spa, or sample cup/bucket). Extension cable can be
removed and probe can be directly attached to the meter as well.
3. Press the ON/OFF button. The most recent measurement will always appear along with the DISK icon.
4. Press the START button to begin a new measurement.
5. During the new measurement, the HOURGLASS indicator will blink before all stabilized parameters
are achieved. Allow up to 20 seconds for testing to complete.
6. When measurement is finished, unit will beep and newest data will be displayed. The data will be
saved in the memory until the next measurement. Only the latest measurement is stored and all prior
measurements are discarded.
7. When finished using the meter, press the ON/OFF button once to turn the device off or the meter will
turn off automatically after 1 minute.
8. Always rinse the probe with fresh tap water after each use and store in carrying case.
Note: Calibrate before first use.
QUICK START GUIDE
Need help?
Do you have a question about the SALTDIP Pro and is the answer not in the manual?
Questions and answers