GasLab Pro Series Operation Manual

GasLab Pro Series Operation Manual

Multi-gas sampling datalogger

Advertisement

Quick Links

GasLab
Pro Series
®
Multi-Gas
Sampling Data Logger
Operation Manual
Popular Models
100% CO2 - CM-1000-00-00-25-00
10% CO2 - CM‐1000-00-00-00-25
25% O2 - CM-1000-00-00-52-00
25% O2 + 100% CO2 - CM-1000-00-52-25-00
Up to 64 Customizable Sensor
Configurations
Copyright © CO2Meter, Inc. All Rights Reserved. March 18, 2021

Advertisement

Table of Contents
loading

Summary of Contents for GasLab Pro Series

  • Page 1 GasLab Pro Series ® Multi-Gas Sampling Data Logger Operation Manual Popular Models 100% CO2 - CM-1000-00-00-25-00 10% CO2 - CM‐1000-00-00-00-25 25% O2 - CM-1000-00-00-52-00 25% O2 + 100% CO2 - CM-1000-00-52-25-00 Up to 64 Customizable Sensor Configurations Copyright © CO2Meter, Inc. All Rights Reserved. March 18, 2021...
  • Page 2: Table Of Contents

    CONTENTS WELCOME ........................3 IMPORTANT SAFEGUARDS ..................3 PACKAGE CONTENTS ....................4 PRODUCT OVERVIEW ....................5 RINCIPAL OF PERATION ..........................NSTRUMENT VERVIEW ............................ DEVICE DIAGRAMN ....................6 LCD DISPLAY ................................Powering/Operation ......................7 QUICK START GUIDE ....................7 DATA LOGGING......................8 SETTINGS ........................
  • Page 3: Welcome

    Thank you for selecting the CM-1000 Gaslab Pro, Multi-Gas Sampling Data Logger. The CM‐1000 series is WELCOME designed to simultaneously measure multiple gas concentrations through a sampling method. This device ® features Li‐ion rechargeable batteries which allows for 30+ hours of use.
  • Page 4: Package Contents

    Please verify that your package contains the following items before using the meter: PACKAGE CONTENTS ALL UNITS: (1) CM‐1000 Multi Gas Data Logger (3) Li‐ion 18650 3.7V batteries (Installed) • (1) Water Trap • (1) Hydrophobic Filters • (2) Particulate Matter filters •...
  • Page 5: Product Overview

    PRODUCT OVERVIEW The GasLab® Pro Multi‐Gas Sampling Data Logger is designed to simultaneously measure multiple gas concentrations through a sampling method. Utilizing a micro pump, the device draws samples into the sensing chambers allowing each sensor to take a fast and accurate measurement of the sample.
  • Page 6: Instrument Overview

    INSTRUMENT OVERVIEW Left Arrow Button K. Pump Button P. Luer Caps Power Switch On/Off Q. Battery Cover Screw Right Arrow Button Temp/Humidity Sensor L. USB Socket R. Battery Cover LCD Displays Screen Down Arrow Button M. SD Card Slot S. Inlet Cap Rubber Enclosure Mode Button N.
  • Page 7: Quick Start Guide

    QUICK START GUIDE 1. Install filters and tubing included if necessary. 2. Turn the meter ON by switching the red power switch up on the left of the device. 3. Turn logging ON by pressing the PUMP button until the SD Card Icon displays a green inner square.
  • Page 8: Data Logging

    DATA STORAGE Once the GasLab® Pro Multi Gas Sampling Data Logger is turned on, you can gather data in real time. Data logs can be downloaded from the device’s micro SD Card to an excel/csv. file and analyzed for further observation. The full color LCD display also features real‐time data graphing by rotating the device to the horizontal position.
  • Page 9: Settings

    The settings screens will allow the user to access all the parameters, options, outputs, communications, and date/time SETTINGS settings available in the device. The settings screen allows you to change the brightness and back‐light color themes (4 available) on the device, as well as activate a back‐light time specifically to save power.
  • Page 10: Using The Filters

    USING THE FILTERS To use this device properly, hoses/tubing must be attached to the inlet and outlet barb fittings securely. The device was shipped with extra luer fittings if they are needed. The micro pump inside the device will draw air from the inlet by vacuum effect, push it through the sensing chamber, and then exhaust the air outside the meter through the outlet port.
  • Page 11: Calibration

    All units are shipped factory calibrated. Factory calibration certificates are saved on the SD card included CALIBRATION with your device. Over time all sensors require recalibration to maintain their accuracy and repeatability. When it is time to re‐ calibrate, end users have two choices: field/self‐calibration OR returning the device to CO2Meter for factory calibration.
  • Page 12: User Calibration

    User Calibration ‐ CM‐1000 ‐ 1 Point Calibration To enter 1‐Point Calibration Mode, please follow the appropriate steps below: The CM‐1000 GasLab® Pro Multi Gas Sampling Data Logger Series is calibrated using 100% CO2 Gas 1. Turn on CM‐1000 and wait for display to initialize.
  • Page 13: Specifications

    SPECIFICATIONS : 1%, 5%, 10%, 20%, 30%, 100% CO: 0~1,000ppm : 0~25%, < 2% FS / 0.1 mbar Measurement Range & : 5% 0-1%: ≤±0.1% Accuracy RH: 0~100%, ±3% @25°C (20~80%RH), others ±5% Temperature: 0~50°C,±1℃ Barometer: 50~110kPa, ±0.4kPa : 1ppm, 10ppm, or 100ppm CO: 1ppm : 0.01% : 0.01%...
  • Page 14: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Possible Cause / Resolution Symptom / Pump does not If the user experiences issues with pump activation, press/hold the Issue ACTIVATE MODE key to enter into settings screen. Click ENTER to access 2/2 and modify “Flow Rate Level” to “5”. If pump is still inactive, pump needs to be replaced –...
  • Page 15: Product Maintenance

    Safety and Product Care To ensure correct and safe device use, please read the User Manual before using the device. Please handle the device lightly, do not subject the device to impact/shock. 1. Do not submerse the device in water or allow liquid to be sampled into the device. This will cause electric shock, fire or malfunction which may result in damage.

Table of Contents