Installation Manual BM-11-401 Mount
General
Please read this BM-11-401 Mount installation manual carefully in order to profit fully from its benefits.
Take care that the mounts and load cells are applied within their specifications. Certainly during
installation special attention should be paid to exceptional forces exceeding these specifications.
Dimensions
Description
Top Plate
Bottom Plate
Total Height
Assembly
Before installing the mount into the application, the stay rod assembly should be removed. The mount
should be assembled and set to the installation height at which the load cell is not loaded:
Capacity
Working Height
77 mm
5-50 kg
3.03 inch
77 mm
100-200 kg
3.03 inch
90 mm
250-500 kg
3.54 inch
Table 1
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.
Nr. 2021.10 Installation Manual BM-11-401 Rev2
Page 1/5
Dimension 5 – 200kg
75mm x 90mm
130mm x 90mm
77mm
Installation Height
81 mm
3,19 inch
81 mm
3,19 inch
94 mm
3,70 inch
Dimensions 250 – 500kg
100mm x 120mm
160mm x 120mm
90mm
Mounting Torque Load Cell
15 Nm
20.5 Lb ft
25 Nm
34 Lb ft
40 Nm
54 Lb ft
Zemic Europe B.V.
T: +31 76 50 39480
info@zemic.nl
www.zemiceurope.com

Advertisement

loading

Summary of Contents for Zemic BM-11-401

  • Page 1 Installation Manual BM-11-401 Mount General Please read this BM-11-401 Mount installation manual carefully in order to profit fully from its benefits. Take care that the mounts and load cells are applied within their specifications. Certainly during installation special attention should be paid to exceptional forces exceeding these specifications.
  • Page 2: Installation

    M6 x 6 M6 x 6 Table 2 Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl Nr. 2021.10 Installation Manual BM-11-401 Rev2 www.zemiceurope.com Page 2/5...
  • Page 3 +1 / -1 mm +1 / -1 mm Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl Nr. 2021.10 Installation Manual BM-11-401 Rev2 www.zemiceurope.com Page 3/5...
  • Page 4 5 – 200kg 250 – 500kg Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl Nr. 2021.10 Installation Manual BM-11-401 Rev2 www.zemiceurope.com Page 4/5...
  • Page 5 Don't cut cable at the gland to facilitate removal - please - we cannot test load cells without cables! Zemic Europe B.V. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T: +31 76 50 39480 info@zemic.nl Nr. 2021.10 Installation Manual BM-11-401 Rev2 www.zemiceurope.com Page 5/5...