International comfort products C Series Installation Instructions Manual page 36

Single-stage, psc blower motor 35” tall, high efficiency condensing gas furnace
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
Alternate Power Supplies
This furnace is designed to operate on a utility generated
power which has a smooth sinusoidal waveform. If the furnace
is to be operated on a generator or other alternate power
supply, the alternate power supply must produce a smooth
sinusoidal waveform for compatibility with furnace electronics.
The alternate power supply must generate the same voltage,
phase, and frequency (Hz) as shown in Table 11 or on the
furnace rating plate.
Table 11
Electrical Data
VOLTS- -
HERTZ- -
UNIT SIZE
PHASE
0401410
115-60-1
0401712
115-60-1
0601412
115-60-1
0601716
115-60-1
0801716
115-60-1
0802120
115-60-1
1002116
115-60-1
1002120
115-60-1
1202420
115-60-1
* Permissible limits of the voltage range at which the unit operates satisfactorily.
# Unit ampacity = 125 percent of largest operating component's full load amps plus 100 percent of all other potential operating components' (EAC, humidifier, etc.) full load
amps.
{ Time--delay type is recommended.
} Length shown is as measured one way along wire path between unit and service panel for maximum 2 percent voltage drop.
Figure 43
Isolation Relay for Humidifiers with Internal Power Supply
To Humidifier Leads
To Humidifier Leads
36
N9MSB SINGLE- -STAGE, PSC BLOWER FURNACES
OPERATING VOLTAGE
RANGE*
MAXIMUM
UNIT
Maximum*
Minimum*
AMPS
127
104
5.2
127
104
7.4
127
104
5.3
127
104
8.6
127
104
8.1
127
104
8.6
127
104
7.3
127
104
11.9
127
104
11.9
Specifications subject to change without notice.
Power from an alternate power supply that non-sinusoidal may
damage the furnace or cause erratic furnace operation.
Contact
the
alternate
power
specifications and details.
MINIMUM
WIRE
UNIT
SIZE
AMPACITY#
AWG
7.5
14
10.3
14
7.6
14
11.7
14
11.1
14
11.7
14
10.1
14
15.8
12
15.8
12
To HUM 24 VAC Terminal
On Furnace Control Board
24 V
Coil
To C Screw Terminal
on Thermostat Strip
Gas Furnace: N9MSB
supply
manufacturer
MAXIMUM
MAXIMUM
FUSE OR CKT
WIRE LENGTH
BKR
FT (M)}
AMPS{
49
(14.9)
15
36
(11.0)
15
48
(14.6)
15
31
(9.4)
15
33
(10.1)
15
31
(9.4)
15
36
(11.0)
15
36
(11.0)
20
36
(11.0)
20
A11157
440 01 4104 07
for