Step 2 Checking And Preparing Accessories And Tools; Step 3 Fixing The Outdoor Unit In Place - Samsung AJ TXJ KH Series Installation Manual

Table of Contents

Advertisement

Installation Procedure
Step 2 Checking and preparing
accessories and tools
3-wire
Power Cable (option)
Drain Plug
Rubber Leg
Flare Nuts, 15.88 mm
outer pipe diameter
Tube connector
(Pipe 12.70 mm, Bolt 9.52 mm)
NOTE
• Attach Energy Label to the outdoor unit properly when
installing.
• Wire assembly cables are optional. If they are not
supplied, use standard cables.
• The drain plug and the rubber legs are included only
when the air conditioner is supplied without assembly
pipes.
• If these accessories are supplied, they are in the
accessory package or outdoor unit package.
8
English
2-wire
Assembly Cable (option)
Energy Label
U.S. Government
Federal law prohibits removal of this label before consumer purchase.
Heat Pump
Samsung Electronics Co., Ltd.
Cooling and Heating
Model AJ036JCJ5CH
Split System
Heating Capacity 40,000 Btu/h
Cooling Capacity 36,000 Btu/h
Cooling
Efficiency Rating
(SEER)*
16.5-18.5
This system's
efficiency ratings depend
14.0
30.5
on the coil your contractor
Least Efficient
Most Efficient
installs with this unit. The
Range of Similar Models
heating efficiency rating
* Seasonal Energy Efficiency Ratio
varies slightly in different
geographic regions. Ask
your contractor for details.
Heating
Efficiency Rating
(HSPF)*
9.0-9.5
For energy cost info, visit
8.2
13.5
productinfo.energy.gov
Least Efficient
Most Efficient
Range of Similar Models
* Heating Seasonal Performance Factor
Installation Manual
Flare Nuts, 9.52 mm
outer pipe diameter
Tube connector
(Pipe 12.70 mm, Bolt 15.88 mm)
Step 3 Fixing the outdoor unit in
place
Install the outdoor unit on a rigid and stable base to
prevent disturbance from any noise caused by vibration.
When installing the unit on tall stands or in a location
exposed to strong winds, fix the unit securely to the
ground or structure.
1 Position the outdoor unit so that the air flow is directed
towards the outside, as indicated by the arrows on the
top of the unit.
2 Attach the outdoor unit to the appropriate support
using anchor bolts.
• The ground wire for the telephone line cannot be
used to ground the air conditioner.
3 DIf the outdoor unit is exposed to strong winds, install
shield plates around the outdoor unit, so that the fan
can operate correctly.
NOTE
• Install provided rubber legs to prevent vibration and
noise.
Rubber leg
CAUTION
• Install a drain outlet at the lowest end around the base
for outdoor unit drainage
• When installing the outdoor unit on the roof,
waterproof the unit and check the ceiling strength.
620 mm

Advertisement

Table of Contents
loading