  • Page 1 Questo manuale d’istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per HP J9829A o cerca il tuo prodotto tra le migliori offerte di Switch HP Switch zl2 Internal Power Supplies Installation Guide Power over Ethernet...
  • Page 3 HP Switch zl2 Internal Power Supplies Installation Guide...
  • Page 4 Nothing herein should be construed as constituting an additional warranty. HP 8-port 10GBASE-T v2 zl Module J9546A HP shall not be liable for technical or editorial errors or HP 8-port 10GbE SFP+ v2 zl Module J9538A omissions contained herein.
  • Page 5: Table Of Contents

    Contents Description ............1 Included Parts .
  • Page 7: Description

    HP Switch zl2 Internal Power Supplies Description The HP Switch zl2 Internal Power Supplies (J9828A, J9829A or J9830A) are redundant power supplies that you can add to any of the HP zl2 switches to provide additional switch reliability. Features: ■...
  • Page 8 Description Figure 1. The J9828A PoE Power Supply Figure 2. The J9829A PoE Power Supply...
  • Page 9: Included Parts

    Description Figure 3. The J9830A Power Supply Included Parts The Switch zl2 Internal Power Supply has the following components shipped with it: ■ Documentation kit...
  • Page 10 Description ■ Power cord, one of the following: Country/Region J9830A Power Supply Cable Australia/New Zealand 8121-1550 China 8121-1551 Mainland Europe/South Korea 8121-1554 India 8121-1074 Japan/Thailand 8121-1555 Denmark/Switzerland 8121-1287 United Kingdom/Hong Kong/Singapore/ 8121-1549 Malaysia United States/Canada 125V 8121-1553 South Africa 8121-1552 Taiwan/USA 250V 8120-6362 Israel...
  • Page 11 Description Country/Region J9828A Power Supply Cable Australia 8121-0834 China 8120-8707 Europe/South Korea 8120-6811 Japan 8120-4753 Thailand/Philippines 8121-0668 India 8121-0780 Denmark 8120-6814 Switzerland 8120-6815 United Kingdom/Hong Kong/Singapore/ Malaysia 8120-6809 South Africa 8120-6813 Taiwan 8121-0974 Israel 8121-1035 Argentina 8120-6869 Brazil 8121-1069 Chile 8120-6980 USA/Canada 8121-0914...
  • Page 12: Installing The Power Supply

    Installing the Power Supply Installing the Power Supply Installation Cautions: ■ When installing multiple power supplies for a switch, use the same power supply type. ■ Make sure the power source circuits are properly grounded, then use the power cord supplied with the power supply to connect it to the power source.
  • Page 13: Installation Steps

    Installing the Power Supply Installation Steps Follow these steps to install the power supply into the back of the switch: Remove the power supply slot cover with either a flat-bladed or Torx T-10 screwdriver. Retain the slot cover for future use. C a u t i o n Make sure the AC power is not connected to the power supply being installed before installing the power supply into the switch.
  • Page 14 During the installation, make sure that AC power is NOT connected to the unit being installed. N o t e Although the illustration shows an HP 5406R zl2 switch, the installation procedure is the same for all zl2 switches. Tighten the four retaining screws that hold the power supply in place until the screws are secure, as shown in the next illustration.
  • Page 15 Power Supply. N o t e The Switch zl2 Internal Power Supply does not have a power switch. It is powered ON when the power cord is connected to the supply and to a power source.
  • Page 16 Installing the Power Supply Verify the power supply is installed correctly by checking the LEDs on the front of the switch. The following example shows an 5406R zl2 switch. Figure 7. Switch Power Status and Fault LEDs The status LED for the power supply, on the management module bulkhead, you have just installed will be flashing simultaneously with the Fault LED until that new power supply is connected to an AC power source.
  • Page 17: Troubleshooting

    Packard offers support 24 hours a day, seven days a week through the use of a number of automated electronic services. See the Customer Support/ Warranty booklet that came with your switch or power supply for information on how to use these services to get technical support. The HP networking products Web site, www.hp.com/networking/support also provides up-to-date support information.
  • Page 18: Specifications

    18.92 cm (7.45 in) Depth: 15.87 cm (6.25 in) Height: 12.95 cm (5.1 in) Electrical The HP zl2 Internal Power Supplies automatically adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz. Electrical J9828A J9829A J9830A...
  • Page 19: Environmental

    Specifications Environmental Operating Non-Operating Temperature: 0°C to 45°C (32°F to 113°F) -40°C to 70°C (-40°F to 158°F) Relative humidity: 15% to 85% at 40°C (104°F) 15% to 90% at 65°C (149°F) (non-condensing) Maximum altitude: J9828A 3.0 km (10,000 ft) 4.6 km (15,000 ft) J9829A 3.0 km (10,000 ft) 4.6 km (15,000 ft)
  • Page 20: Safety Information

    Safety Information Safety Information Documentation reference symbol. If the product is marked with this symbol, refer to the product documentation to get more information about the product. WARNING A WARNING in the manual denotes a hazard that can cause injury or death.
  • Page 21: Informations Concernant La Sécurité

    Informations concernant la sécurité Informations concernant la sécurité Symbole de référence à la documentation. Si le produit est marqué de ce symbole, reportez-vous à la documentation du produit afin d'obtenir des informations plus détaillées. WARNING Dans la documentation, un WARNING indique un danger susceptible d'entraîner des dommages corporels ou la mort.
  • Page 22: Hinweise Zur Sicherheit

    Hinweise zur Sicherheit Hinweise zur Sicherheit Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation nach, um mehr Informationen über das Produkt zu erhalten. WARNING Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation nach, um mehr Informationen über das Produkt zu erhalten.
  • Page 23: Considerazioni Sulla Sicurezza

    Considerazioni sulla sicurezza Considerazioni sulla sicurezza Simbolo di riferimento alla documentazione. Se il prodotto è contrassegnato da questo simbolo, fare riferimento alla documen- tazione sul prodotto per ulteriori informazioni su di esso. WARNING La dicitura WARNINGdenota un pericolo che può causare lesioni o morte.
  • Page 24: Consideraciones Sobre Seguridad

    Consideraciones sobre seguridad Consideraciones sobre seguridad Símbolo de referencia a la documentación. Si el producto va marcado con este símbolo, consultar la documentación del producto a fin de obtener mayor información sobre el producto. WARNING Una WARNING en la documentación señala un riesgo que podría resultar en lesiones o la muerte.
  • Page 25: Safety Information (Japan)

    Safety Information (Japan) Safety Information (Japan) J a p a n P o w e r C o r d W a r n i n g...
  • Page 26: Safety Information (China)

    Safety Information (China) Safety Information (China)
  • Page 27: Emc Regulatory Statements

    EMC Regulatory Statements EMC Regulatory Statements U.S.A. FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference when the equipment is operated in a commercial environment.
  • Page 28: Korea

    EMC Regulatory Statements Korea Taiwan...
  • Page 29: Recycle Statements

    Recycle Statements Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements Disposal of Waste Equipment by Users in Private Household in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste.
  • Page 30 Recycle Statements Laitteiden hävittäminen kotitalouksissa Euroopan unionin alueella Jos tuotteessa tai sen pakkauksessa on tämä merkki, tuotetta ei saa hävittää kotitalousjätteiden mukana. Tällöin hävitettävä laite on toimitettava sähkölaitteiden ja elektronisten laitteiden kierrätyspisteeseen. Hävitettävien laitteiden erillinen käsittely ja kierrätys auttavat säästämään luonnonvaroja ja varmista- maan, että...
  • Page 31 Recycle Statements Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non può essere smaltito insieme ai rifiuti domestici. È responsabilità dell'utente smaltire le apparecchiature consegnan- dole presso un punto di raccolta designato al riciclo e allo smaltimento di apparecchiature elettriche ed elettroniche.
  • Page 32 Para obter mais informações sobre locais que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido.
  • Page 33: Regulatory

    8000 Foothills Blvd., Roseville, CA 95747 U.S.A (Hg) (Cd) declares, that the product (Pb) (Cr(VI)) (PBB) Product Name: HP 5406R zl2 Switch HP 5412R zl2 Switch J9850A, J9851A, J9821A, J9822A Product Model(s): Regulatory Model Number: RSVLC-1301 (PCA) Product Options: conforms to the following Product Specifications and Regulations:...
  • Page 34 Regulatory...
  • Page 36 © Copyright 2005-2012,2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.