Table 5. MCM Input Reference Settings Page 1 Setting Descriptors
SETTING
1PPS
10MHz
CrossLink Ref-A Slot
CrossLink Ref-B Slot
CrossLink Ref-A Rx
CrossLink Ref-B Rx
Reference Select
Manual Ref Select
Reference AutoSwitch
Priorities
Displays Yes when the M212's MCM is receiving pulses via
the 1PPS port.
Displays Yes when the M212's MCM is receiving frequency
via the 10MHz input connection.
Displays the slot that optical CrossLink input reference A is
installed in.
Displays the slot that optical CrossLink input reference B is
installed in.
Displays the port that optical CrossLink input reference A is
connected to.
Displays the port that optical CrossLink input reference B is
connected to.
Properties
Switch the MCM between automatic and manual reference
selection.
If the MCM is set to manual reference selection, this selects
which source is used.
For each of the input references listed, select a numerical
value to assign each input source's priority, with 1 being
the most important.
Once set, the MCM will try to use the input reference source
listed as 1, but if that fails, it will automatically switch to
input reference 2 if it is valid. If the lower-priority input
reference is not valid, the M212 will iterate down to a
lower priority input reference until a higher priority input
reference is restored.
31
MANUAL P/N 900000178 REV B
DESCRIPTION