Specifications; Electrical And Refrigerant Data - Hoshizaki KMD-860MWJ Instruction Manual

Modular crescent cuber
Hide thumbs Also See for KMD-860MWJ:
Table of Contents

Advertisement

I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. KMD-860M_J
Model Number
KMD-860MAJ
AC Supply Voltage
208-230/60/1
Compressor
208-230V 7.7RLA 46LRA
Pump
120V 0.5FLA 60W
Fan
120V 1.0FLA (TOTAL)
1/15HP
Other
115-120V 0.8A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
20 AMPS
(USA Only)
Max. Circuit Breaker
20 AMPS
(Canada Only)
Minimum Circuit
20 AMPS
Ampacity
Design Pressure
HI-467PSI LO-230PSI
Refrigerant
404A 2 LB. 6.8 OZ.
Single Phase
KMD-860MWJ
208-230/60/1
208-230V 7.2RLA 46LRA
120V 0.5FLA 60W
--- --- ---
115-120V 0.8A
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-427PSI LO-230PSI
404A 1 LB. 12.2 OZ.
6
KMD-860MRJ
208-230/60/1
208-230V 8.2RLA 56LRA
120V 0.5FLA 60W
120V 3A MAX (Fan in URC)
115-120V 0.15A
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-467PSI LO-230PSI
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-9F: 9 LB. 14.8 OZ.