5. Remote Condenser Unit URC-14F (use with KM-1301SRJ/3)

NOTICE
Allow 24" (61 cm) clearance
at front and rear for proper
air circulation and ease of
maintenance and/or service
should they be required.
URC-14F Heat of Rejection
Icemaker
AT 90°F (32°C)
Model
WT 70°F (21°C)
KM-1301SRJ
17,600 BTU/hr
KM-1301SRJ3
17,500 BTU/hr
6. Remote Condenser Unit URC-22F (use with KM-1601SRJ/3, KM-1900SRJ/3,
KM-2200SRJ3) and URC-26J (use with KM-2600SRJ3)
NOTICE
Allow 24" (61 cm) clearance
at front and rear for proper
air circulation and ease of
maintenance and/or service
should they be required.
Icemaker
Model
URC Model
KM-1601SRJ
URC-22F
KM-1601SRJ3
URC-22F
KM-1900SRJ
URC-22F
KM-1900SRJ3
URC-22F
KM-2200SRJ3
URC-22F
KM-2600SRJ3
URC-26J
Data Pending
Heat of
Rejection
AT 90°F (32°C)
WT 70°F (21°C)
21,000 BTU/hr
26,400 BTU/hr
26,500 BTU
Data Pending
/hr
25,700 BTU/hr
30,800 BTU/hr
40,600 BTU/hr