JetAir JASA18HP230V1AD Owner's Manual page 20

Slim concealed duct unit
Table of Contents

Advertisement

OPERATING INSTRUCTIONS
Setup and Configuration Modes
INDOOR FAN MODE
The unit has two selectable indoor fan operating modes:
Mode 0 (Factory default setting): The indoor fan will run continuously, except in heat mode,
where the indoor fan will continue to run for 60 seconds after room temperature reaches setpoint.
Mode 1: The indoor fan will turn Off 10 seconds after the room temperature reaches
setpoint, regardless of the mode.
Indoor Fan Mode Setting
Turn the unit Off, Press the Function and Timer buttons simultaneously for 5 seconds until 00
is displayed on the temperature display. Press Mode button until 05 is displayed. Then press
▲ and ▼ buttons to select the desired indoor fan mode ( '00' for Mode 0 or '01' for Mode 1).
Press Enter/Cancel button to activate.
F
F
F
Turn Unit Off.
Simultaneously, press Function and Timer
buttons for 5 sec until '00' is displayed.
F
Press Enter/Cancel to activate.
Cancel Indoor Fan Mode
To cancel, press Enter/Cancel button
and quit from the interface.
Press Mode button until "05" is shown
on the temperature display area.
F
F
F
Press ▲ or ▼ button to select
F
an indoor fan mode.
19

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for JetAir JASA18HP230V1AD

Table of Contents