Operating Instructions

Checking for Leaks
W WARNING: Before using this outdoor
fireplace, make sure you have
read, understand and are following
all information provided in the
"Important Safeguards" section.
Failure to follow those instructions
can cause death, serious injury or
property damage.
Burner Connections
1 .
Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank .
2 .
Visually check the connection between the
burner/venturi tube and orifice .
3 .
Make sure the burner/venturi tube fits over the
orifice .
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
4 .
Please refer to diagram for proper installation
(Figures 1 and 2) .
5 .
If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1 .800 .762 .1142 for assistance .
Tank/Gas Line Connection
1 .
Make 2-3 oz . of leak detection solution by
mixing one part liquid dishwashing soap with
three parts water .
2 .
Make sure control knobs are in the " OFF"
position (Figure 3) .
3 .
Connect LP gas tank per "Installing LP Gas
Tank" section .
4 .
Turn LP gas tank valve to "OPEN ."
5 .
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1 and 2) .
a . If any bubbles appear, turn LP gas tank valve
to "CLOSED," reconnect and re-test .
b . If you continue to see bubbles after
several attempts, turn LP gas tank valve to
"CLOSED" and disconnect LP gas tank, per
"Disconnecting LP Gas Tank" section . Contact
1 .800 .762 .1142 for assistance .
c . If no bubbles appear after one minute, turn
LP gas tank valve to "CLOSED," wipe away
solution and proceed .
Lighting
W WARNING: NEVER light the burner
with the cover on the outdoor
fireplace.
W CAUTION: Keep outdoor gas
appliance area clear and free from
combustible materials, gasoline and
other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of
combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1 .
Make sure all labels, packaging and protective films have been removed from the outdoor
fireplace .
2 .
Check for obstructions of airflow to the burner . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner tube can lead to a fire .
3 .
Control knob must be in the " OFF" position (Figure 3) .
4 .
Clear small area of lava rocks / glass rocks away from the igniter cover (Figure 4) .
5 .
Connect LP gas tank per "Installing LP Gas Tank" section .
6 .
Turn LP gas tank valve to "OPEN ."
7 .
Push and turn control knob to (HIGH) . Continue to hold the control knob in to light .
8 .
After the fire table lights, continue to hold the control knob in for 20 seconds to heat the
thermocouple, a safety device that stops the gas flow when a firepit is not lit . Holding the
knob in for 20 seconds warms it up so the gas flow will continue .
9 .
After 20 seconds, release and turn control knob counterclockwise to adjust flame to
desired height .
10 . After three attempts, if ignition does not occur, turn the burner control knob to " OFF ."
Figure 1
Burner Venturi
Pipe
LP Gas
Connection
X
X
X
X
X
X
LP Gas Valve
with Orifice
Burner Supply
Tube
Figure 2
X
X
X
X
X
Figure 3
OFF / APAGADO
Figure 4
Figure 5
11.8 in. – 19.7 in.
30 – 50 cm
Replacement Parts
1.800.762.1142
11 . Wait 5 minutes, fan with a newspaper or magazine, and repeat lighting procedure .
12 . If igniter does not light burner:
a .
Wearing heat-resistant gloves, position a long lit match or long lit butane lighter near
the igniter cover .
b .
Push and turn control knob to (LOW) .
c .
Remove match/lighter once burner is lit .
W CAUTION: After lighting - using a fireplace tool and heat-resistant
gloves, carefully move the lava rock / glass rock back to their proper
position, being careful to avoid the flame.
13 . After lighting, observe the burner flame . Make sure all burner ports are lit and flame height
matches illustration (Figure 5) .
W CAUTION: If ignition does not occur in 5 seconds, turn control knob
to " OFF," wait 5 minutes, fan with a newspaper or magazine, and
repeat lighting procedure.
Turning Off
1 .
Turn LP gas tank valve to "CLOSED ."
2 .
Turn control knob to the " OFF" position .
Note: A "poof" sound is normal as the last of the LP gas is burned .
3 .
Disconnect LP gas tank per "Disconnecting LP Gas Tank" section .

Cleaning and Care

W CAUTION:
1. All cleaning and maintenance should be done when outdoor
fireplace is cool and with the fuel supply disconnected.
2. Do NOT clean any outdoor fireplace part in a self-cleaning oven.
The extreme heat will damage the finish.
3. Do NOT enlarge valve orifices or burner ports when cleaning the
valves or burners.
4. All components on this outdoor fireplace can become hot.
5. Do NOT clean this outdoor fireplace until all components are cool.
Notices
1.
This outdoor fireplace should be thoroughly cleaned and inspected on a regular
basis.
2.
Abrasive cleaners will damage this product.
3.
NEVER use oven cleaner to clean any part of this outdoor fireplace.
Before Each Use:
1 .
Keep the outdoor fireplace area clear and free from any combustible materials, gasoline,
and other flammable vapors and liquids .
2 .
Do NOT obstruct the flow of the combustion of LP gas and the ventilation of air .
3 .
Keep the ventilation opening(s) of the LP gas tank area free and clear from debris .
4 .
Visually check the burner flames to make sure your outdoor fireplace is working properly
(Figure 5) .
5 .
See below for proper cleaning instructions .
6 .
Check all gas connections for leaks .
7 .
Check components for any signs of damage or rust .
8 .
Check for obstructions of airflow to the burner . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner/venturi tube can lead to a fire .
9 .
If damage to any component is detected, do NOT operate until repairs are completed .
Cleaning Surfaces
1 .
Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water .
2 .
For stubborn stains, use a citrus-based cleaner and a nylon scrubbing brush .
3 .
Rinse clean with water .
4 .
Allow to air dry .
Before Storing
1 .
Turn LP gas tank valve to "CLOSED ."
2 .
Turn control knob to the " OFF" position .
Note: A "poof" sound is normal as the last of the gas is burned .
3 .
Disconnect LP gas tank per "Disconnecting LP Gas Tank" section .
4 .
Clean all surfaces .
5 .
Lightly coat the burner with cooking oil to prevent excess rusting .
W CAUTION: NEVER place cover on hot outdoor fireplace.
6 .
If storing the outdoor fireplace indoors, cover the outdoor fireplace and store in a cool dry
location away from children and pets .
7 .
If storing the outdoor fireplace outdoors, cover the outdoor fireplace with a cover for
protection from the weather .