3. GeNeRAl iNsTRUcTioNs
WARNiNG! ensure the light is disconnected from the mains power supply before attempting any of the following.
3.1.
Telescopic sTANDs
3.1.1.
Loosen the locking screw on the leg collar (fig.3A) and slide the collar down to spread the legs
outward, when the legs are in the desired position tighten the locking screw.
3.1.2.
to extend the upright support, loosen the locking collars (fig.3B) at the end of each section,
raise the inner support to the required height and tighten the locking collars.
3.1.3.
fit the lights to the top of the stand passing the thumb screw through the lamp bracket and the
stand then secure with nut.
3.1.4.
fix the junction box onto the bolt in at the top of the stand (fig.3c), with one light each side.
check that the electrical cable runs directly down the stand to the floor. Do NoT allow the
cable to extend across the workshop above floor level.
check that the assembly is secure and that all nuts and bolts are tight (Do NoT overtighten).
3.1.5.
stand light on a suitable, level surface before use.
3.2.
BUlB cHANGiNG
WARNiNG! Disconnect the light from the power supply and allow to cool before
attempting to touch the unit.
Do NoT touch the new halogen bulb as the natural oil from your fingers will shorten the
bulb life. Handle with a dry, clean cloth only.
3.2.1.
Loosen the screw on the top of the front cover (fig.4) and undo, allowing the front cover to
open. check to ensure that the screw is retained in the front cover tab (fig.4.3) by the washer.
3.2.2.
remove the old bulb and discard. Hold the new bulb (fig.4.1) in a clean cloth and insert it
(always use the correctly rated bulb).
3.2.3.
check that the weather seal is correctly located in the rim (fig.4.4) and the washer is on the
securing screw. close the font cover. seal by tightening the securing screw.
3.3.
GeNeRAl
use only original sealey parts for repair or replacement. repairs must only be undertaken by a
qualified electrician.
clean the light with a dry, dust-free cloth. Do NoT use solvents or abrasives to clean the light.
Avoid touching the glass shield (fig.4.2) as handling may reduce service life and cause the
glass to crack. If necessary clean the shield (when cold) with alcohol and a soft cloth. If the
glass is damaged, replace it immediately. use genuine sealey replacement glass. Do NoT use
other glass and Do NoT use the light without the glass shield.
Although weather proof, the light must not be stored wet. should the unit become wet, unplug
from mains and wipe dry before storing.
Do NoT use the light without the weather seal intact.
recycle unwanted materials instead of disposing of them as waste.
All tools, accessories and packaging should be sorted, taken to a recycle centre and disposed of in a manner which is compatible
with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way. contact your local solid waste
authority for recycling information.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMpoRTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
iNFoRMATioN: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
fig.4
environmental protection
sole UK Distributor, sealey Group,
Kempson Way, suffolk Business Park,
Bury st. Edmunds, suffolk,
IP32 7Ar
Original Language Version
www.sealey.co.uk
01284 757500
Web
01284 703534
sales@sealey.co.uk
email
ML1000D/110V.V3
fig.3
Issue: 1 - 14/12/11

Advertisement

loading