  • Page 1 Egg Station Model ES-600, ES-602, ES-604, ES-800 & ES-1200 owner’s manual Manufacturing Numbers: 9300530, 9300531, 9300532, 9300571, 9300574, 9300575, 9300577, 9300581, 9300591, 9300593, 9300598, 9300599, 9300621, 9300622, 9300623 www.antunes.com P/N 1010883 Rev Y 06/18...
  • Page 2: Table Of Contents

    Damage caused by improper installation, abuse, or careless handling. IMPORTANT Damage from moisture getting into electrical components. Antunes reserves the right to change Damage from tampering with, specifications and product design without removal of, or changing any notice. Such revisions do not entitle preset control or safety device. the buyer to corresponding changes,...
  • Page 3: Important Safety Information

    This equipment should be Do not use an extension serviced by qualified personnel cord with this appliance. only. Contact Antunes Technical Service for adjustment or repair. Electrical ground is required on this appliance. Do not block or cover any openings on the unit.
  • Page 4: Specifications

    SPECIFICATIONS 7 9/32" READY 2'-00" BACON 2'-30" COOKING START/STOP POWER 16 5/8" Model & Model & Volts Watts Hertz Description Configuration Mfg. No. Mfg. No. ES-600 ES-600 2400 11.5 50/60 9300530 9300530 9300531 11.5 / ES-600 208/220 2400 / 10.9 50/60 ES-602 9300531 - 240~ 3150...
  • Page 5: Installation

    WARNING tom legs of the unit to level it. Failure NOTE: If any parts are missing or dam- to level the table and/or unit may re- ELECTRICAL SHOCK aged, contact Antunes Customer HAZARD. Failure to follow sult in unevenly cooked product. Service IMMEDIATELY at +1-877- 392-7856 (toll free). the instructions in this manual could result in 2. Remove information packet.
  • Page 6: Operating Instructions

    OPERATING 6. Select the desired cooking cycle 9. At the end of the cycle, when the (Figure 3). Cooking Indicator Light turns off, INSTRUCTIONS All units Except Mfg. No. press the Start/Stop button to turn 9300534: off the audio signal. Preparing Unit Use a two-minute cycle for room 10. All units EXCEPT Mfg. No.
  • Page 7: Bacon Timer

    Bacon Timer* (All units EXCEPT Mfg. No. 9300534) READY 2'-00" If, during the standby mode, the Bacon BACON Indicator Light is not lit, it means that the 2'-30" Bacon Timer is disabled. To enable the COOKING POWER START/STOP Bacon Timer, with the unit turned on, FOR MFG. NO. 9300530, 532, 571, 574, 575, 581, & 593: press the TIME 1 and TIME 2 buttons si- NOTE - THE FOLLOWING ARE FACTORY PRE-SET COOKING TIMES.
  • Page 8: Maintenance

    MAINTENANCE Checking Cycle Times 5. Clean the Egg Rings, Egg Rack, Cover, and Service Pans in hot, (Monthly) WARNING soapy water. Rinse these items in (Mfg. No. 9300534 ONLY) clear water and allow to air dry. Turn the power off, unplug the power cord, NOTE: A stopwatch is required for this 6. Reassemble the unit. and allow the unit to cool down before procedure.
  • Page 9: Best Practices/Troubleshooting For Under Cooked Eggs

    Best Practices/Troubleshooting Troubleshooting Eggs leaking Checking Grill Platen for Under Cooked Eggs out of Egg Rings Temperature WARNING 1. Level unit - adjust feet if neces- Egg Ring Replacement depends on us- sary. The unit must be level before age but in general, Egg Rings should be This procedure exposes you to hot sur- use.
  • Page 10: Troubleshooting

    Inoperable electrical outlet. Plug the power cord into a different outlet of same amperage rating. Inoperable power switch. Contact your maintenance person or Antunes Technical Service at +1-877-392-7854 (toll free). Inoperable power cord. Loose connections. Unit fails to heat.
  • Page 11: Control Board Leds

    Control Board LEDs STATUS The control Board has three on Solid State Green 50 AMP 24-280 VAC Relay board LEDs (Figure 5) to determine 1/L1 2/T1 Crouzet the status of the unit and to assist in Bauart YELL gapruit PRODUCT SERVICE Yellow troubleshooting.
  • Page 12: Wiring Diagram

    WIRING DIAGRAM P/N 1010883 Rev. Y 06/18...
  • Page 13: Replacement Parts

    REPLACEMENT PARTS P/N 1010883 Rev. Y 06/18...
  • Page 14 NOTE: Item 1 for Mfg. No. 9300132 uses a different Left Side Panel than other units contained in this manual. This allows the power cord for 9300132 to be located on the Left side of the unit rather than on the front of the unit. The new Left Side Panel part numbers is 0506673. P/N 1010883 Rev. Y 06/18...
  • Page 15 Replacement Parts can be purchased from an authorized dealer. Contact Antunes Customer Service at +1-877-392-7856 (toll free). Item Part # Description Qty. Item Part # Description Qty. Item Part # Description Qty. 0021327 Nose Piece Weldment 0504078 Bracket, Hi-Limit 4010137 Switch, Rocker (25A-250V) 210K230 Bumper, Recess Leg 0700323 Power Cord Assembly 4010187 Transformer, Stepdown 1” (Set of 4 including 4 6-20P, 20 Amp., 250...
  • Page 16: Limited Warranty

    Travel Time & Mileage in excess of 2 hours (100 miles/160 km) round trip from the nearest authorized service agency. Antunes reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations.