Summary of Contents for Fitel S218R-Plus

  • Page 1 FTS-B553-04 S218R-Plus Hot Stripper Operating Instructions • Please read entire manual prior to usage. • Please keep this manual with the S218R-Plus. Issue 03 Apr. 2019...
  • Page 2: Table Of Contents

    FTS-B553-04 Contents Contents ......................1 Safety Instructions ..................2 Components ....................5 2.1 Standard Components ................5 2.2 Optional Components ................5 Specifications .................... 5 Unit Description ..................6 Preparation ....................7 5.1 Battery setting ..................7 5.2 Charging the Battery ................8 Operating Instruction .................
  • Page 3: Safety Instructions

    • If the S218R-Plus is dropped and damaged, disconnect the power source. Continuing to operate under these conditions may cause fire or electrical shock. • Do not operate the S218R-Plus at temperatures less than 0ºC or above 40ºC. Do not expose to high temperatures. Doing so may cause fire, electrical shock or malfunction.
  • Page 4 • Do not use in a humid, dirty or vibration site. Doing so may cause fire, electrical shock or malfunction. • Do not place the S218R-Plus on an unstable or inclined surface. The S218R-Plus may fall and cause injury. • Disconnect all cords when using DC cord and moving the S218R-Plus. Doing so may damage the cords which may cause fire or electrical shock.
  • Page 5 FTS-B553-04 Notes This symbol mark is for EU countries only. This symbol mark is according to the directive 2006/66/EC Article 20 Information for end-users and Annex II. This symbol means that batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste. If a chemical symbol is printed beneath the symbol shown above, this chemical symbol means that the battery or accumulator contains a heavy metal at a certain concentration.
  • Page 6: Components

    FTS-B553 2.2 Optional Components Name Code Quantity Remarks Single Fiber Adapter S218X-03 The adapter for stripping single fiber Blade for S218R-Plus S218X-88 1(set) See manual in 11 Replacing the blade Battery Pack S944 Li-Ion Rechargeable Battery AC→DC Converter AC adaptor...
  • Page 7: Unit Description

    FTS-B553-04 4 Unit Description Min. line Max. line Fiber ribbon Indication lamp (25mm) (35mm) Blade Holder clamp (LED) Power Switch Heater Fiber holder Heater lid Holder clamp lid Blade Top side (with the Fiber holder) Contact Bottom side (without Battery cover) Mode switch Temperature Trimmer Screw for the Battery cover...
  • Page 8: Preparation

    FTS-B553-04 5 Preparation 5.1 Battery setting Mount the S944 Battery Pack into the S218R before using it. 1) Loosen the screw of the Battery cover by using an Phillips-head screwdriver. 2) 2) Remove the Battery cover by pushing it to the direction as shown at right.
  • Page 9: Charging The Battery

    FTS-B553-04 5.2 Charging the Battery 1) Let S944 battery Pack be remained in S218R Hot Stripper. 2) Connect S952 AC adaptor to AC power outlet (85-264V, 50/60Hz) using AC power cord. 3) Connect S218R Main body to S952 AC adaptor using DC plug cable. 4)...
  • Page 10: Operating Instruction

    The mode can be changed by setting mode switch to “SAVE” position. In the save mode, S218R-Plus cuts heater power and reduces the power consumption to a few mA during the waiting time. So it will take more time to raise the heater temperature enough for use after leaving in this mode for a...
  • Page 11: Recharging Battery

    FTS-B553-04 9 Recharging Battery Attach S944 battery to the S218R-Plus and charge it using S952 AC adapter. 10 Confirming Battery Remaining During using S218R with S944 battery, continuing to press the power switch for more than 2 seconds will cause the S218R to show the battery power remaining with indication lamp. (Green/Red LED) Each state of LED shows the condition of the battery and remaining power as per following table.
  • Page 12: Replacing The Upper Blade

    FTS-B553-04 12.2 Replacing the upper blade 1) Loosen two upper blade adjusting screw with attached 0.9mm hex wrench. Do not remove the screw, only loosen it. 2) Remove two upper blade set screws, and take off the upper blade. 3) Set the new lower blade tentatively with the set screw tightened slightly. Blade can be adjusted manually with light touch behind body.
  • Page 13: Others

    FTS-B553-04 13 Others 13.1 The usage of the Adjusters (spacer) The adjusters is used when changing cleave length. Head of fiber holder Fiber coating Fiber Clad Cleave length (Y) Fiber coating length (X) Fiber holder The adjuster has three kinds of thickness: 1mm, 2mm and 3mm. 1mm,2mm,3mm Following is a guide table showing how to use the adjuster and its combination to make right stripping length.
  • Page 14: Mounting The Stand (Optional Parts) For The Unit

    FTS-B553-04 13.2 Mounting the Stand (Optional parts) for the unit 1) Remove the Battery cover. 2) Put the stand to the unit, then tighten the screw. Screw the stand Remove the Battery cover 13.3 Single fiber adapter (Optional parts) installation. Φ0.25mm~Φ0.4mm)...
  • Page 15: Storage For The S944 Battery Pack

    If S944 Battery Pack needs to be stored for more than 1 month without being used, please store it using the following procedure. Remove the S944 Battery Pack from S218R-Plus Main body, then move that to proper storage area. Maintain the storage environment under following conditions, temperature: -20°C to +20°C, and humidity: 15 to 95 %RH without condensing.